Table of Contents
6.3.1.3
Multiple Connections Topology
In a multi-axis application it is likely that a single power supply can feed several drives in parallel.
The power supply is connected directly to the mains AC line and it feeds more than one drive.
This topology is efficient and cost saving, by reducing the number of power supplies and the
amount of wiring. Most importantly it utilizes an energy sharing environment among all the drives
that share the same DC bus network.
Figure 17: Non-Isolated Three-Phase Multiple Connection Topology