Gold DC Whistle Installation Guide
MAN-G-DCWHIIG-EC (Ver. 1.705)
||Main and Auxiliary Power|
29
6.3.2.
Main Power (J13)
Pin (J13)
Signal
Function
Cable
1
VP+
Positive Power input
DC Power
2
PR
Power return
DC Power
3
PE
Protective Earth
DC Power
3-Pin Phoenix 5 mm Pitch ‘HC’
3-Pin Phoenix Plug-in
Connector
Table 4: Connectors for Main Power
Connect the DC power cable to the VP+ and PR terminals on the Main Power Connector.
To connect the DC power supply:
1.
The source of the 12 to 195 VDC power supply must be isolated.
2.
For best immunity, it is highly recommended to use twisted and shielded cables for the DC
power supply. A 3-wire shielded cable should be used. The gauge is determined by the
actual current consumption of the motor.
3.
Connect the cable shield to the closest ground connection near the power supply.
4.
Connect the PE to the closest ground connection near the power supply.
5.
Connect the PR to the closest ground connection near the power supply.
6.
Before applying power, first verify the polarity of the connection.
Содержание G-DCWHI Series
Страница 64: ... www elmomc com 64 Table of Contents ...