8
•
Using the auto-iris lens
The following table shows the IRIS terminal when using the auto-iris (EE) lens.
Table 1
The IRIS connector used for the IRIS terminal: HR10A-7P-6P of HIROSE ELECTRIC
CO., LTD.
•
EE lens
The IRIS extension cable (optional) is usable for the EE lens. Use the connector HR10A-
7P-4P of HIROSE when the IRIS extension cable is selected. For connections, follow the
instruction below.
When the IRIS extension cable is used under
the right condition, the cable automatically
converts to connection for the EE lens in
Table 1.
Notes:
•
Current consumption must be 50 mA or less.
•
Avoid an incorrect connection or short-circuit.
USING CAMERA CONTROL IN FIXED POSITION
The camera control unit can be directly mounted by using M3 screws if the four rubber
feet are removed on bottom of the control unit. When mounting directly as described
above, do not use longer screws. If the screws enter by more than 5 mm from the control
unit mounting surface, they will cause a short-circuit inside the control unit. For details of
screw hole locations, refer to “PROFILE” of the camera control unit.
IRIS Connector
Terminal No.
1
2
3
4
5
6
EE lens connector
HR10A-7P-4P
1.
Power (+)
2.
GND
3.
Video signal
4.
Unconnected or ground
Rated
0.8
±
0.1Vp-p
+ 12V (less than 50mA)
Signal
––
Video signal
GND
Power (DC)
(GND)
––