Servicing
Keypad
(PC)
1)
Malfunction
Cause
Remedy
Carried
out by
Mains voltage too low
Check mains voltage
DC
−
bus voltage too low
Check supply module
LU
DC
−
bus
undervoltage
400 V frequency inverter
connected to 230 V mains
Connect frequency inverter to the
correct mains voltage.
Electrician
Short
−
circuit
Search for cause of short
−
circuit;
check motor cable.
Operator
Electrician
OC1
(11)
Short
−
circuit
Excessive capacitive charging
current of the motor cable
Use shorter motor cable with
lower charging current..
Electrician
Grounded motor phase
Check motor, check motor cable
OC2
(12)
Earth fault
Excessive capacitive charging
current of the motor cable
Use shorter motor cable with
lower charging current.
Electrician
Acceleration time too short
(C0012)
Increase
acceleration
time
Check
drive
dimensioning
U
min
- boost (C0016) set too
large or too small
Correct setting
Only for operation with
control cabinet inverter
2FCxxxx
−
2NE00
U/f- rated frequency (C0015)
set too small
Correct setting
Differential pressure too high
Check differential pressure of the
system.
Side channel blower starts at
half throttle
Increase
acceleration
time
Open
valves.
Operator
Frequency
inverter overload
during
acceleration
Impeller jammed
Repair side channel blower.
Service
*)
Defective motor cable
Check wiring.
OC3
(13)
Short
−
circuit
Interturn fault in the motor
Check motor.
Electrician
Deceleration time too short
(C0013)
OC4
(14)
Frequency
inverter overload
during
deceleration
Energy backflow in generator
mode operation too high
Increase deceleration time.
Operator
OC5
(15)
Frequency
inverter overload
in stationary
operation
Frequent and too long overload Check dimensioning of side
channel blower.
Operator
OC6
(16)
Motor overload
(I
2
x t - overload)
Motor is thermally overloaded,
for instance, because of
impermissible
continuous
current
frequent or too long
acceleration processes
Check dimensioning of side
channel blower.
Operator
OH
(50)
Heatsink
temperature> +85
°C
Ambient temperature too high Allow frequency inverter to cool
down and ensure better
ventilation.
Operator
Heatsink strongly polluted
Clean heatsink
Check dimensioning of side
channel blower..
Operator
OH
Heatsink
temperature> +80
°C
Impermissibly high currents or
frequent and too long
accelerations
Check
load,
if
necessary,
replace defective bearings
Service
*)