background image

G-Serie

G-Series

Seitenkanal 

Side Channel

 

 

Edition: 12.2009 · 610.44521.40.000 

Original operating instructions · English

 

Operating Instructions G-BH1e

 

 

 

 

 

 

2BH13..-..N 
2BH14..-..N 
2BH15..-..N 
2BH16..-..N 
2BH18..-..N

 

 

 

 

Содержание 2BH13 N Series

Страница 1: ...G Serie G Series Seitenkanal Side Channel Edition 12 2009 610 44521 40 000 Original operating instructions English Operating Instructions G BH1e 2BH13 N 2BH14 N 2BH15 N 2BH16 N 2BH18 N...

Страница 2: ...level 11 2 1 3 Temperature increase 11 2 2 Electrical data 12 2 3 General data operating conditions 13 3 Transport and handling 14 3 1 Transport devices 14 3 2 Transport types 14 4 Installation 15 4 1...

Страница 3: ...50 Design of side channel blowers in conjunction with frequency inverters 1 4 7 2 3 11 5 6 8 9 10 2bhxn402 Position Description 1 Frequency inverter 2 Inlet connection with muffler and arrow indicati...

Страница 4: ...e 33 5 Adapt important process parameters Adapt acceleration and deceleration time to the hydraulic process via C0012 and C0013 Description of parameter changing starts on page 34 6 Adjust the speed A...

Страница 5: ...r serious injury if the corresponding measures are not taken WARNING Danger of injuries Indicates a potentially hazardous situation that could result in death or serious injury if the corresponding me...

Страница 6: ...gainst being switched on again Determine whether deenergized Ground and short circuit Cover or block off adjacent energized parts DANGER Electrical danger Do not open the frequency inverter until abse...

Страница 7: ...r unit through open connections Do not insert objects into the pump motor unit through the openings WARNING Danger from rotating impeller cutting cutting off of extremities The rotating impeller is ac...

Страница 8: ...surement in the system during operation after installing the pump motor unit The following measures must be taken by the operator from 85 dB A Hearing protection must be available from 90 dB A Mark no...

Страница 9: ...ese persons must be trained and authorized for the work to be carried out Work on electrical installations may be carried out by trained and authorized electricians only G BH1e series side channel blo...

Страница 10: ...e gases can occur to extract deliver and compress explosive flammable corrosive or toxic media to operate the pump motor units with values other than those specified in the chapter Technical data Any...

Страница 11: ...400 7 N1 63 64 74 2BH1400 7 N2 63 64 74 2BH1500 7 N3 64 70 75 2BH1600 7 N3 69 72 80 2BH180 7 N0 70 74 81 2BH180 7 N1 70 74 81 Two impeller design 2BH1310 7 N2 55 61 66 2BH1410 7 N4 66 69 77 2BH1510 7...

Страница 12: ...read Nm lb in M4 2 7 3 3 23 9 29 2 M5 3 6 4 4 31 9 38 9 M6 7 2 8 8 63 7 77 9 M8 21 6 26 4 191 234 M10 37 8 46 2 335 409 M12 63 0 77 0 558 681 Tightening torques for cable and conduit glands Metal Thre...

Страница 13: ...al pressure difference indicated on the rating plate by 0 7 C 0 4 F Operation at higher temperatures may damage the winding and shorten the grease change interval Temperature of pumped gases max 40 C...

Страница 14: ...ds 3 1 Transport devices All pump motor units with a weight of more than 30 kg are equipped with an eye bolt at the side channel housing The crane hook can be hooked directly into the eye bolt Alterna...

Страница 15: ...ng surface regularly for strength and firm seating WARNING Danger of crushing due to pump motor unit tipping over Wear personal safety equipment safety gloves and safety shoes Handle the pump motor un...

Страница 16: ...fler if necessary 4 Connect inlet and discharge connections to the system 5 Establish electrical connection 4 1 Installation CAUTION Pump motor unit damage caused by incorrect mounting or use under im...

Страница 17: ...the atmosphere Noise protection hoods available as accessories Noise protection hoods are suitable for installation in rooms and in the open They reduce the overall sound pressure level and tonal comp...

Страница 18: ...ey come with a stud bolt on one side and a threaded hole on the other side WARNING Danger of crushing caused by pump motor unit tipping over Avoid free standing installation of the pump motor unit Alw...

Страница 19: ...oose for packaging related reasons It must be mounted by the operator 2BH1310 2BH1610 two impeller pump motor units with two stage design ne2bhxn004b Fig 8 Mounting of the muffler 2BH1310 2BH1610 WARN...

Страница 20: ...relief valve upstream if necessary NOTE Attach pipes hoses free of mechanical tensions Support the weight of the pipes hoses 4 3 2 Connecting the inlet line WARNING Danger from solid bodies and impur...

Страница 21: ...ump motor unit is touched Have electrical equipment checked regularly by a qualified electrician 4 4 1 Important notes Regulations The electrical connection must be carried out as follows according to...

Страница 22: ...3 5 mA The PE connection must meet EN 50178 Observe national and regional regulations CAUTION Danger of pump motor unit damage caused by improper connection Observe the permissible mains voltage Any...

Страница 23: ...motor temperature monitoring PES HF shield termination by large surface connection to PE Mains contactor fuses and cable cross sections NOTE Observe the following when using earth leakage circuit brea...

Страница 24: ...se two screws at terminal X1 and remove the terminal B Pass the mains cable through the cable gland C Attach the ring cable lug 5 3 mm to the PE conductor D Screw the PE conductor onto the PE stud for...

Страница 25: ...caused by improper connection Observe the permissible mains voltage Any higher mains voltage will destroy the frequency inverter Wiring according to EMC requirements installation of a CE typical driv...

Страница 26: ...re cable ne2bhxn045 2 Insert cable tie ne2bhxn046 3 Insert cable and tighten cable tie The shielding must have large surface contact to the shield sheet The shielding must be connected tightly to the...

Страница 27: ...nstallation according to UL 1 Type L1 L2 L3 PE mm2 L1 L2 L3 PE AWG 2FC4302 1NE00 M16 A B16 A 2 5 15 A 14 2FC4402 1NE00 M20 A B20 A 4 20 A 12 2FC4552 1NE00 M25 A B25 A 4 25 A 10 2FC4752 1NE00 M32 A B32...

Страница 28: ...ments 26 C Connect cores to terminal X1 observe terminal connection diagram and tightening torque 3 Connecting the control cable shield A Pass the control cable through the cable gland B Connect the s...

Страница 29: ...end ferrule 1 0 mm2 AWG 18 without wire end ferrule without plastic sleeve 0 5 mm2 AWG 20 with wire end ferrule with plastic sleeve 0 5 mm2 AWG 20 Tightening torque 0 22 0 25 Nm 1 9 2 2 lb in Bare en...

Страница 30: ...P Reset HIGH Reset fault HIGH Switch off with fault indication EEr X3 E2 External fault LOW No fault E3 E4 X3 E3 34 Hz 2000 min HIGH LOW 67 Hz 4000 min LOW HIGH X3 E4 Digital inputs Activation of fixe...

Страница 31: ...ble entries must be tightly closed so as to make them dustproof and waterproof Check for tightness at regular intervals DANGER Electrical danger Danger of electrical shock when a defective pump motor...

Страница 32: ...stallation 2FC4152 1NE00 2FC4222 1NE00 2 4 Nm 21 lb in IP65 ne2bhxn227 Fig 21 Close frequency inverters 2FC4152 1NE00 and 2FC4222 1NE00 2FC4302 1NE00 2FC4752 1NE00 1 1 Nm 9 7 lb in IP65 ne2bhxn459 Fig...

Страница 33: ...connections of the pipe hose connections lines fittings and containers for strength leaks and firm seating at regular intervals 5 1 Preparation WARNING Danger from closed connections With closed soil...

Страница 34: ...rea with a warning sign Wear hearing protection With free entry and exit of gases i e with direct intake out of the atmosphere or direct feeding into the atmosphere without piping attach an additional...

Страница 35: ...r every mains connection Code selection Four digit display of the active code number Without function Is skipped Change of parameter value of a code Five digit display of the current value Without fun...

Страница 36: ...olumn Abbreviation Meaning Cxxxx Code number Cxxxx The parameter value is accepted immediately ONLINE Changed parameter of the code will be accepted after pressing Code Changed parameter of the code w...

Страница 37: ...2FCxxxx 1NE00 inverter 10 00 Setting for units up to 5 5 kW 20 00 Setting for 7 5 kW unit C0013 Deceleration time main setpoint 0 00 0 02 s 1300 00 Reference frequency change 0 Hz C0011 Only valid for...

Страница 38: ...inlet line or in the pressure line 4 Switch on the mains misc002 5 The keypad is in Disp mode after approx 2 s and indicates the setpoint offset C0140 Set 6 Change to the mode with in order to set dr...

Страница 39: ...ia terminals 7 8 9 Terminal E3 E4 34 Hz 2000 min HIGH LOW 67 Hz 4000 min LOW HIGH 12 C Enter fixed speed via terminal 50 Hz 3000 min HIGH HIGH 13 Enable controller misc002 Terminal X3 28 HIGH 14 The d...

Страница 40: ...ation Allow to cool after shut down CAUTION Danger of overheating due to hot surface of pump motor unit High temperatures of up to approx 160 C 320 F can occur on the surface of the pump motor unit Te...

Страница 41: ...an environment with a temperature of over 40 C 104 F the winding may be damaged and the grease change interval may be shortened Lubrication of the rolling bearings after longer storage The new pump mo...

Страница 42: ...ary Service Impeller defective Replace impeller Service Rolling bearing on drive motor side or vacuum pump compressor side defective Replace motor bearing or vacuum pump compressor bearing Service Red...

Страница 43: ...Electrician Operator Side channel blower operates setpoints 0 In C0140 a setpoint has been set Setting of C0140 stored in non volatile memory Set C0140 0 Hz if necessary Electrician Operator Current c...

Страница 44: ...connected from the bus Check if there is a bus termination Check shield contact of the cables Check PE connection Check bus load if necessary reduce the baud rate Service ce5 66 CAN time out For remot...

Страница 45: ...ck differential pressure of the system Side channel blower starts at half throttle Increase acceleration time Open valves Operator Frequency inverter overload during acceleration Impeller jammed Repai...

Страница 46: ...er indicated by the PC parameter setting program in preparation Can only be repaired by the operator if the maintenance manual is on hand 8 1 4 Fault indication reset TRIP RESET 20 28 X3 3 1 OFF 4 6 O...

Страница 47: ...iled information must be provided on request if necessary The pump motor unit may not present a danger to the workshop personnel Pump motor units with contact to hazardous substances must be decontami...

Страница 48: ...Disposal Have the entire pump motor unit scrapped by a suitable disposal company Ensure recycling of metals and plastics Assembled PCBs need to be disposed of professionally For additional informatio...

Страница 49: ...mation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEC 2006 42 EC Directive 2006 42 EC of the European Parliament and of the Council of 17...

Страница 50: ...heet The unit system was used in the following application and has come into contact with the following classifiable substances or substances presenting a hazard to health environment Trade name Chemi...

Страница 51: ...Gardner Denver Deutschland GmbH 51 52 610 44521 40 000 Form for statement on safety...

Страница 52: ...ations www gd elmorietschle de er de gardnerdenver com Gardner Denver Schopfheim GmbH Roggenbachstra e 58 79650 Schopfheim Deutschland Tel 49 7622 392 0 Fax 49 7622 392 300 Gardner Denver Deutschland...