18
Output current adjustment
The EVDuty EVC30 Series charging station offers the possibility to adjust the maximum output current. This
adjustment may be necessary in the case where the charging station must be powered by a circuit which is protected
by a circuit breaker of a value less than 40 A. Table 3 is used to determine the value of the maximum output current
based on the value of the circuit breaker that protects the charging station.
To adjust the maximum output current, perform the following steps:
1. Disable the electrical circuit that powers the charging station by setting the appropriate circuit breaker to « OFF »
in the main electrical panel.
2. Disconnect the charging station’s input power cable (either from the wall receptacle or from the junction box,
depending on the model) and remove it from its wall-mount bracket.
3. Remove the six (6) screws holding the back plate to the charging station’s enclosure.
4. Remove the back plate.
5. Using a small flat screwdriver, modify the state of the DIP Switch by moving the small white levers to the left or
to the right according to the desired value. Please refer to Figure 5 and Figure 6 and also to Table 4 and Table 5
depending on the revision of the control circuit board installed in the unit.
6. Do the sequence of steps 1 to 4 in reverse for the reinstallation of the charging station.
CIRCUIT BREAKER VALUE (A)
MAXIMUM OUTPUT CURRENT (A)
15
12
20
16
25
20
30
24
40
30
Table
3: Maximum output current vs circuit breaker value