Technical Support Line +44 (0)23 9269 6638 2405STE PAK200479 Issue 04I May 2016
Page 4 of 4
M
AINTENANCE
There is no regular maintenance required of the PSU as the microcontroller performs regular health checks of the battery and output voltage.
However, reference should be made to the battery manufacturer’s documentation to determine typical / expected battery life with a view to
periodic replacement of the battery.
If the output of the PSU fails the cause of the failure should be investigated e.g. short circuit load, connection of a deeply discharged battery. The fault
should be rectified before restoring power to the PSU. The following fuses may need to be replaced. Ensure the correct fuse rating and type is used.
Load Output Fuse
F5A 20mm, 250Vac glass
Internal Mains Fuse
T3.15A 20mm, 250Vac HBC
Battery Fuse
F5A 20mm, 250Vac glass
CAUTION
Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the
battery manufacturer’s instructions and all local and national regulations