ms FUEL INJECTION DETECTOR function
Trigger level defaults at 3. Press the Level (RANGE) button momentarily to select another
trigger level. If the reading becomes unstable, select lower sensitivity to avoid electrical
noise. If the reading shows zero, select higher sensitivity. Number of Bar-graph pointer is
used to indicate sensitivity selected.
Positive & negative trigger slopes are selectable through pressing
TRIGGER button for
one second or more.
Press SELECT button momentarily 3 times to display ms reading in terms of percentage
(%) if required
Note: This -ms function applies to both Port Fuel Injectors (PFI) which operate with a
single on time pulse and Throttle Body Injectors (TBI) which operate with twin pulses