User Instruction
8
Figure 1
SPECIFICATIONS
Sides:72 in. /
182.9 cm
Top:48in. /
121.9cm
30,000 Btu/hr
11 inches water
column
INPUT
Propane Regulator
Pressure
Clearances to
combustible
surfaces
A self-contained LP-gas cylinder for use with this appliance must have a capacity of 20
lbs. and must be equipped with a Type 1 connector and an OP D (overfill protection
device). See Figure 1.
The LP-gas supply cylinder to be used must be constructed and marked in accordance
with the specification for LP- gas cylinders of the U.S. Department of Transportation (DOT)
or the National Standard of Canada, CAN/CSA-B339, Cylinder, Sphere and Tubes for the
Transportation of Dangerous Goods.
●
The cylinder supply system must be arranged for vapor withdrawal.
●
The cylinder used must include a collar to protect the cylinder valve.
●
This appliance shall be used only outdoors in a well-ventilated space and shall not be
used in a building, garage or any other enclosed space.
●
When this appliance is not is use, the gas must be turned off at the supply cylinder.
●
Storage of this appliance indoors is permissible only if the cylinder is disconnected and
removed from the appliance.
IMPORTANT SAFETY INFORMATION
WARNING
Cylinders must be stored outdoors in a well-ventilated area out of
the reach of children.
Disconnected cylinders must have threaded valve plugs tightly
installed and must not be stored in a building, garage or any other
enclosed areas.
Storing cylinders indoors or in poorly ventilated spaces outdoors
can result inserious bodily injury and/or death.
CSA (Canadian Standards Association) certified to ANSI
Z21.97•CSA 2.41- 2017 “ Outdoor Decorative Gas Appliances”.