SAFETY TIPS.

page 1

WARNING

:  To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit 

panel before you begin the fan installation or before servicing the fan or installing accessories.

1.        

 READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN AND 

SAVE THESE INSTRUCTIONS.

CAUTION

:  To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.

2.         Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and 

ANSI/NFPA 70-1999.  If you are unfamiliar with electrical wiring or if the house/building wires are different 
colors than those referred to in the instructions, please use a qualified electrician.

3.         Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at 

least seven (7) feet (2.13 meters) of clearance between the floor and the fan blade tips.  The fan should be 
mounted so that the tips of the blades are at least thirty (30) inches (76 centimeters) from walls or other 
upright structures.

4.         The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 

35 pounds (16 kilograms).  The outlet box must be supported directly by the building structure.  Use only 
CUL (Canada) or UL (USA) listed outlet boxes marked "FOR FAN SUPPORT."

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked 

"Acceptable for Fan Support of 15.9 kg (35 lb) or less," and use the mounting screws provided with the outlet box.  
Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may 
need to be replaced.  Consult a qualified electrician if in doubt.

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are 

designed to accept only one 12 gauge house wire and two lead wires from the fan. If your house wire is larger than 
12 gauge or there is more than one house wire to connect to the corresponding fan lead wires, consult an 
electrician for the proper size wire connectors to use.

5.         Electrical diagrams are for reference only.  Light kits that are not packed with the fan must be CUL (Canada) 
 

  or UL (USA) listed and marked suitable for use with the model fan you are installing.  Switches must be  

CUL (Canada) or UL (USA) general use switches.  Refer to the instructions packaged with the light kits and 
switches for proper assembly.

6.         After installation is complete, check that all connections are absolutely secure.
7.         After making electrical connections, spliced conductors should be turned upward and pushed carefully up 

into the outlet box.  The wires should be spread apart with the grounded conductor and the 
equipment-grounding conductor on opposite sides of the outlet box.

WARNING

:  To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control device 

or control fan speed with a full range dimmer switch.  [Using a full range dimmer switch to control fan speed will 
cause a loud humming noise from fan.] (

Note

: This fan 

is

 suitable for use with remote control.)

8.        Do not operate the reverse switch until the fan has come to a complete stop. [

Note

: If using remote                 

control with reverse capability, reverse fan blade direction only when on LOW speed.]

 
9.        Do not insert anything between the fan blades while they are rotating.

WARNING

:  To reduce the risk of personal injury, do not bend the blade arms during assembly or after installation.  

Do not insert objects into the path of the blades.

WARNING

:  To avoid personal injury or damage to the fan and other items, be cautious when working around or 

cleaning the fan.

10.      Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened 

cloth will be suitable for most cleaning.

WARNING

:  To reduce the risk of personal injury, use 

only

 parts provided with this fan.  

The use of parts 

OTHER

 

than those provided with this fan will void the warranty.

NOTE

:  The important safety precautions and instructions appearing in the manual are not meant to cover all 

possible conditions and situations that may occur.  It must be understood that common sense and caution are 
necessary factors in the installation and operation of this fan.

Содержание DUN52PLN5

Страница 1: ...pg 1 Unpacking Your Fan pg 2 Parts Inventory pg 2 Installation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 6 Canopy Assembly pg 7 Blade Assembly pg 7 Switch Housi...

Страница 2: ...nnect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan mus...

Страница 3: ...inst parts inventory that all parts have been included 2 Parts Inventory IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety a canopy 1 piece b hanging...

Страница 4: ...let box If installing on a vaulted ceiling face opening of hanging bracket towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket Note It is very important that...

Страница 5: ...res this will keep the wires together when threading them through the downrod Loosen yoke set screws and nuts at top of motor housing and remove pin and clip from motor housing yoke Slide downrod thro...

Страница 6: ...eek the help of another person to hold the stepladder in place and to help lift the fan up to you once you are set on the ladder Find a secure attachment point wood ceiling joist highly recommended an...

Страница 7: ...from ceiling with wire connector provided Connect WHITE wire from fan to WHITE wire from ceiling with wire connector provided Connect all GROUND GREEN wires together from fan to BARE GREEN wire from...

Страница 8: ...ws lock washers blade arm Time Saver Washers for blade screws can be set on each blade screw prior to installing blades Locate 15 blade attachment screws and washers in one of the hardware packs Hold...

Страница 9: ...plate to lock Re insert screw that was removed and secure all screws diagram a Connect male plug from motor housing to female plug from switch housing Make sure plugs connect tightly diagram b Align...

Страница 10: ...pletely off before moving the reverse switch Set reverse switch to recirculate air depending on the season LEFT position in summer diagram 2 RIGHT position in winter diagram 3 A ceiling fan will allow...

Страница 11: ...ent fan and we will pay the return shipping cost 5 YEAR WARRANTY CRAFTMADE ELLINGTON will repair or replace at no charge to the original purchaser any fan motor that fails to operate satisfactorily wh...

Страница 12: ...para la instalaci n P g 3 Instalaci n del soporte de montaje P g 3 Ensamblaje del ventilador P gs 4 5 Instalaci n el ctrica P g 6 Colocaci n de la cubierta decorativa P g 7 Colocaci n de las aspas P...

Страница 13: ...la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar con un electricista para informarse sobre el tama o correcto de conectores para cable que se debe...

Страница 14: ...icar que se incluyeron todas 2 Inventario de piezas RECORDATORIO IMPORTANTE Se tienen que utilizar las piezas provistas con este ventilador para una instalaci n adecuada y su seguridad a cubierta deco...

Страница 15: ...edado colocar el soporte de montaje con la abertura dirigida hacia la parte alta del techo Arreglar el alambrado el ctrico los cables en la parte de atr s del soporte y lejos de la abertura del soport...

Страница 16: ...pasarlos por el tubo Aflojar los tornillos de fijaci n del cuello y las tuercas en el cuello del bastidor del motor y quitar el perno y la clavija del cuello del bastidor del motor Pasar el tubo por l...

Страница 17: ...puede causar lesiones graves o la muerte Sugerencia Solicitar ayuda de otra persona para mantener la escalera sujeta y para que le suba el ventilador cuando usted ya est preparado en la escalera para...

Страница 18: ...or al cable NEGRO del techo con un conector para cable provisto Conectar el cable BLANCO del ventilador al cable BLANCO del techo con un conector para cable provisto Conectar todos los conductores a T...

Страница 19: ...de seguridad Para ahorrar tiempo Se pueden poner las arandelas en los tornillos que son para las aspas antes de colocar las aspas Localizar 15 tornillos para sujetar las aspas y 15 arandelas en uno de...

Страница 20: ...r el enchufe macho del bastidor del motor al enchufe hembra de la caja de encendido Asegurarse de que se conecten bien los enchufes diagrama b Alinear los agujeros en la caja de encendido con los aguj...

Страница 21: ...el ventilador completamente antes de mover el interruptor de reversa Regularlo para que se circule bien el aire dependiendo de las estaciones del a o posici n IZQUIERDA en verano diagrama 2 posici n...

Страница 22: ...AFTMADE ELLINGTON al 1 800 486 4892 para acordar el reenv o del ventilador Devolver el ventilador con los gastos de env o propagados a Craftmade Ellington Nosotros repararemos o reemplazaremos el vent...