MP500/4N-8-16 Programming
39
24) Press
and then
.
25) Press
. Press
and
to select:
DISPLAY AND to view the input combined to the input being programmed
DISABLE AND to cancel the combination with the other input
SELECT AND to select the input (first the device and then the input) to be combined to the
input being programmed.
Press
to confirm the selection and follow the menu items show below.
26) Press
and then
.
27) Press
. Enter a descriptive name for the input using the keypad (see paragraph
). The name can be up to 24 characters long. Press
to confirm.
28) Press
.
29) Press
. Press
again to play the vocal name of the input.
30) Press
. To record, press
31) Press
. Press
to cancel the vocal message of the input.
32) Press
to program the other inputs of the same device, repeating the procedure from step
5; press
again to program the inputs of another device (expansion modules, keypads,
readers), repeating the procedure from step 3. Use
and
to select another device.
33) Press
repeatedly to exit from the menu.
IMPORTANT!
Program all inputs used in the system.
4.12 WIRED INPUT PROGRAMMING
The MP500/4N, MP500/8 and MP500/16 systems can manage up to 11, 27 and 51 general purpose outputs.
See the
Installation Manual
for more information and for connections.
4.12.1
Output encoding
Each output has two addresses: a physical address and a logical address. The two addresses are displayed as follows:
physical address
→
logical address
and in detail
ddXX
U
Y:
→
U
ZZ
where:
dd
is the bus device type or the control panel (UC, EP, AS)
XX
is the sequential numbering of the bus devices containing the outputs
Y
is the number of the output of the bus device XX
ZZ
is the two-digit logical address of the output that the control panel assigns sequentially as the bus devices are assigned.
The physical address is useful for installers during system installation and maintenance. It may appear in a different manner on the
display (UC=control panel, EP=expansion module, AS=power supply).
The logical address can be changed at any time by the installer.
The system identifies the outputs on the display by showing physical address, logical address and name. Vocal and number alarms, on
the other hand, are identified by means of the logical address and the customised message (if any) only.
The control panel automatically assigns a sequential logical address in sequence to the outputs of the control panel itself during EP500
expansion module acquisition.
UC.In1: In001
AND INPUTS
AND INPUTS
DISPLAY AND
UC.In1: In001
NAME
NAME
Inxxx:...
UC.In1: In001
VOCAL NAME
VOCAL NAME
PLAY
VOCAL NAME
RECORD
VOCAL NAME
DELETE