(((ELKRON))) - MP110
3.5.1 Storage of a New Key
1. Enter the MASTER USER code on the keypad and press keys
F
+
7
in sequence.
2. Press the
1
key several times until the following message appears
on the display:
• keypad with alphanumeric display: “
KEY PROGRAM
”
• keypad with segmented display: “
-
” (one flashing hyphen)
3. Press the
7
key. Commutator led 2 flashes slowly to indicate
system standby for entry of the first key.
4. Insert the commutator key. The system proposes key enabling on all
three zones with the lighting of leds 1, 3 and 4. If this is the desired
configuration, remove the key while led 2 flashes quickly.
5. By leaving the key permanently inserted, the various combinations of
zones with which the key can be associated are displayed with the
lighting of leds 1, 3 and 4, as shown in the table below:
6. When the desired combination has been set, remove the key ONLY
WHILE LED 2 FLASHES QUICKLY.
7.
Re-introduce the key
: If the operation has a positive result, the leds
of the sectors previously associated with the key turn on and led 2
flashes slowly waiting for other keys to be programmed, if any.
8. Remove the key. Return to item 4 to program the other keys or press
F
to exit
slow
flashing
led 1, 3 and 4
ON
1
1
ON
3
ON
4
ON
the key is associated with all 3 zones
2
1
ON
3 OFF
4 OFF
the key is associated with zone1
3
1 OFF
3
ON
4 OFF
the key is associated with zone 2
4
1
ON
3
ON
4 OFF
the key is associated with zones 1and 2
5
1 OFF
3 OFF
4
ON
the key is associated with zone 3
6
1
ON
3 OFF
4
ON
the key is associated with zones 1and 3
7
1 OFF
3
ON
4
ON
the key is associated with zones 2 and 3