54
MEDEA Programming Manual
5.2
Times
This can be used to configure the action times of the system sectors.
It is accessed through the
PROGRAMMATION
→ Times
menu.
Figure 46 - Sector times
If the
All Times as Sector 1
parameter is selected only the times of sector 1 are shown and will apply to all
sectors. If the parameter is disabled, the times set for the other sectors of the system are also displayed
in table form.
The following information is shown for each sector:
•
NUMBER
: This is the number of the sector.
•
DESCRIPTION
: This is the alphanumeric label used to identify the sector more easily. It is set in the
Sectors
submenu.
•
INTRUSION ALARM
: This is the alarm output activation time in seconds (e.g. the time for which the
sirens sound) for intrusion alarms. IMPORTANT! The minimum alarm time for an EN 50131 certified
system is 90 seconds.
•
TAMPER ALARM
: This is the alarm output activation time in sectors (e.g. the time for which the sirens
sound) for burglar alarms.
•
TECHNOLOGICAL ALARM
: This is the activation time of the alarm outputs for technical alarms, in
seconds.
•
DURESS ALARM
: This is the activation time of the alarm outputs for hold-up alarms, in seconds.
•
RESCUE ALARM
: This is the activation time of the alarm outputs for emergency alarms, in seconds.
•
GONG OUTPUT
: This is the time of the gong outputs, in seconds.
•
EXIT PATH
: This is the exit delay time, in seconds.
•
ENTRANCE DELAY 1
: This is the entry 1 delay time, in seconds.
•
ENTRANCE DELAY 2
: This is the entry 2 delay time, in seconds.