BUS CONNECTION 

 

WARNING!  Always  connect  and  disconnect  the  devices  to  the  bus  with  the  control  panel  not 
powered (mains and battery disconnected). 
Refer  to  the  installation  manual  of  MP500/8  control  panel  with  regard  to  the  cable  section, 
distances and extensions. 

 

 

Wires  with  cross-section  area  of  0.5  mm²  or  larger  must  comply  with  IEC  60332-1-2;  wires 

with cross-section area smaller than 0.5 mm²  must comply with IEC 60332-2-2. 

 

Connect the device to the BUS using terminals +, +D, D  and  

 (Legend Fig. 1 - E and Fig.3) 

The device can be connected to the BUS in cascade, star or mixed mode. 
The total length of all bus stretches must not exceed 400 m. 

 

CONFIGURATION 

After  having  positioned  and  wired  the  device  to  the  bus  of  the  control  unit  (operation  to  be 
performed with the control unit not powered) proceed with: 

 

Device acquisition on the bus

 

 

Proceed as follows to perform the acquisition procedure: 
1.  Enter in the acquisition mode from keypad MP500/8 control panel, by typing > Code > Technical 

>OK. 

2.  Press the programming button “PROG when the message "Acquisition in progress" appears 

on the display  (see Legend Fig.1 - A), 

3.  The keypad buzzer sounds and the "Acquisition in progress" message disappears.   
4.  The LED on the board blink quickly three times to indicate that the address has been acquired. 
5.  Then, the LED starts blinking in Access Point mode with normal operation.  

During normal operation, by pressing the programming button PROG” (see Legend Fig.1 - A), the 
board runs a short LED sequence, which specifies the address acquired.

 

 

 

The  IT500CLOUD  interface  board  being  acquired,  is  recognised  by  the  MP500/8  control 

panel as a keypad and the first available address is assigned to it. Pay attention to the number of 
keypads  already  present  in  the  system.  The  maximum  number  allowed  is  8  (e.g.  if  a  board  is 
acquired there may be up to 7 keypads in the system). 

 

Device network parameter configuration

 

 

The device can work both either with Ethernet network or  with WiFi using your home network or 
one  available  in  DHCP  mode.  By  default,  the  device  is  in  "Access  Point"  mode,  it  will  be 
necessary to define the operating mode through the “My Elkron Family” App.  

 

NOTE:  If  the  Ethernet  connection  is  used,  this  mode  can  be  enabled  directly,  following  the 
instructions below: 

 

  When the interface is operating (two blink every 8 seconds) press the “PROG” button 5 times”.

 

  After the command wait a few moments (about 20 seconds), the interface restarts and goes into 

the chosen mode (Ethernet). 

  Power off the interface, wait 10 seconds, and power up the interface again. 

 

Proceed as follows to configure: 
Power the control unit, if you have chosen to connect it to your home network via cable (Ethernet), 
connect it to the connector on the device (see legend Fig. 1 - F). 

 

Start the My Elkron Family application previously installed and proceed as follows: 

 

Press the “Other” button. 

 

Select the "Add Device" menu. 

 

Follow the instructions which will appear on the guided menu. 

 

If  all  the  parameters  were  programmed  correctly,  the  device  is  ready  to  be  managed  via  the  My 
Elkron Family App. 

Содержание IT500CLOUD

Страница 1: ...T26 001B LBT81043 FR EN IT IT500CLOUD Interfaccia per App My Elkron Family Interface for My Elkron Family App Interface pour l application My Elkron Family Manuale Utente User Manual Manuel de l Utilisateur ...

Страница 2: ...montaggio alla configurazione ed alle prove funzionali bisogna avere a disposizione un dispositivo mobile Smartphone o Tablet dove installare l App dedicata My Elkron Family disponibile e scaricabile da Play Store o App store Per poter installare e utilizzare l applicazione occorre disporre per dispositivi Android versione 5 0 o superiore per dispositivi IOS versione 10 0 o superiore Il modulo può...

Страница 3: ...eda esegue una breve sequenza Led che specifica l indirizzo acquisito La scheda interfaccia IT500CLOUD in fase di acquisizione viene riconosciuta dalla centrale MP500 8 come Tastiera e gli viene assegnato il primo indirizzo disponibile Prestare attenzione al numero di tastiere già presenti nel sistema in quanto il numero max consentito è di 8 per esempio se si acquisisce la scheda dovranno essere ...

Страница 4: ... Segnalazione led Reset hardware lampeggio per 10 secondi Scheda resettata in modo Access Point non acquisita su centrale 1 lampeggio ogni circa 2 secondi Scheda resettata in modo Access Point acquisita 2 lampeggi lenti con intervallo di 8 secondi tra una sequenza e l altra Scheda collegata alla rete WiFi LAN a acquisizione rete indirizzo IP b rete acquisita in ricerca Cloud Elkron certificato c r...

Страница 5: ...iguration and functional tests a mobile device Smartphone or Tablet must be available to install the dedicated App My Elkron Family available and downloadable from the Play Store or App store In order to install and use the application you must have for Android devices version 5 0 or higher for IOS devices version 10 0 or higher The module can be installed in three different ways Inside the MP500 ...

Страница 6: ...mming button PROG see Legend Fig 1 A the board runs a short LED sequence which specifies the address acquired The IT500CLOUD interface board being acquired is recognised by the MP500 8 control panel as a keypad and the first available address is assigned to it Pay attention to the number of keypads already present in the system The maximum number allowed is 8 e g if a board is acquired there may b...

Страница 7: ... Hardware Reset blink for 10 seconds Board reset in Access Point mode not acquired by control panel 1 blink approximately every 2 seconds Board reset in Access Point mode acquired 2 slow blinks with an interval of 8 seconds between sequences Board connected to WiFi LAN a Network IP address acquisition b Acquired network searching for Elkron Cloud certificate c Network acquired Cloud certificate ac...

Страница 8: ...andable ATTENTION Avant de procéder à l installation de configuration et de fonctionnement un dispositif mobile Smartphone ou Tablette doit être disponible pour installer l App dédiée My Elkron Family disponible et téléchargeable depuis le Play Store ou l App Store Pour installer et utiliser l application vous devez avoir pour les dispositifs Android version 5 0 ou supérieure pour les dispositifs ...

Страница 9: ...se acquise La carte d interface IT500CLOUD en cours d acquisition est reconnue par la centrale MP500 8 en tant que clavier et on lui attribue la première adresse disponible Faire attention au nombre de claviers déjà présents dans le système car le nombre maximum autorisé est 8 par exemple si j acquiers la carte le système doit avoir un maximum de 7 claviers Configuration des paramètres de réseau d...

Страница 10: ... secondes Carte réinitialisée en mode Access Point non acquise sur la centrale 1 seul clignotement toutes les 2 secondes environ Carte réinitialisée en mode Access Point acquise 2 clignotements lents avec un intervalle de 8 secondes entre les séquences Carte connectée au réseau WiFi LAN a Acquisition du réseau adresse IP b Réseau acquis recherche en cours de Cloud Elkron certificat c Réseau acquis...

Страница 11: ...and Programming PROG button B QR Code label C 4 way dip switch D Tamper E Terminal board for bus F Ethernet RJ45 connector G Led system status Reset Parameter Dip switch Use DIP 1 Not used DIP 2 Not used DIP 3 Not used DIP 4 Tamper Legend Figure 1 Figura 1 Figure 1 Figure 1 A Bouton de RAZ et programmation PROG B Etiquette QR Code C Commutateur DIP à 4 voies D Tamper E Bornier bus F Connecteur Eth...

Страница 12: ...12 IT500CLOUD ALLOGGIAMENTO NEL CONTENITORE OPZIONALE CP EP500 LOCATION IN THE OPTIONAL CP EP500 BOX LOGEMENT DANS LE BOITIER OPTIONNEL CP EP500 4 5 6 3 2 1 Figura 2 Figure 2 Figure 2 ...

Страница 13: ...OUD D Espansione filare EP508 o IT500CLOUD Location Device C Wired expansion EP508 or radio ER600 or IT500CLOUD D Wired expansion EP508 or IT500CLOUD Logement Dispositif C Extension filaire EP508 ou radio ER600 ou IT500CLOUD D Extension filaire EP508 ou IT500CLOUD Fondo box centrale MP500 8 Box bottom of the MP500 8 control panel Fond de la boîte de la centrale MP500 8 Figura 3 Figure 3 Figure 3 ...

Страница 14: ...te indirizzo Internet www elkron com SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby Urmet S p A declares that the radio equipment type IT500CLOUD Interfaces is in compliance with Directive 2014 53 UE The full text of the EU declaration of conformity is available at the following internet address www elkron com DECLARATION UE DE CONFORMITE SIMPLIFIEE Le soussigné Urmet S p A déclare que l équipemen...

Страница 15: ...ct or on its packaging indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve n...

Страница 16: ... 011 3986703 www elkron com mail to info elkron it ELKRON è un marchio commerciale di URMET S p A ELKRON is trademark of URMET S p A ELKRON est une marque commerciale d URMET S p A Via Bologna 188 C 10154 Torino TO Italy www urmet com Made in ITALY ...

Отзывы: