4.0 FLASHLIGHT MODULE
On HPA702L, HPA702LG, HPA703XP and HPA703XP/H models, a flashlight module in LED technology is
assembled, that joins together a longer time and reduced consumptions, allowing a longer battery autonomy.
The module has two additional signalling LED available.
The
System Status RED LED
signals the TC signal logic condition:
Off: TC signal present, inactive system;
Blinking: TC signal absent, active system;
The
Failure YELLOW LED
shows the storage of the
first detected
anomaly in a chronological order
(only with TC signal present,
namely with inactive system) by means of a short blinking every 2 s.
It is possible to obtain the detail about failure types (that are signalled
by different blinking), by keeping the “TEST” jumper (present on the
siren module – see paragraph 3.0) short-circuited.
The table shows the different blinking and their meaning.
Memory deletion occurs with the following TC transition (system
activation).
Note: if such luminous signalling are not wanted, disconnect the respective wires from terminals L1 and L2 of
the siren module (see paragraph 3.0).
5.0 PROTECTION MODULE
The HPA703XP - HPA703XP/H sirens are equipped as series with a protection module (optional for HPA702L and
HPA702LG versions) managed by a microprocessor that is able to detect tampering attempts with foam (detection from
both optical circuits is needed), drilling
(electrical contacting between the two cages)
, thermal attacks (fixed threshold
in combination with thermal-speed analysis).
D
SAB-
SAB+
-
+P
TAMPER
Number of
blinking
Meaning
1 Battery
discharged
2 Failed
horn
3 Failed
flash
4
Failed protection
module (if present)
LED
WHITE
YELLOW--GREEN
BLUE
BLACK
RED
NC contact output
L1 - WHITE
+ P - RED
L - BLACK
L2 - YE
LLOW
Red LED
Yellow LED
Red LED
Yellow LED
Basic versions (HPA702L, HPA702LG)
High brightness versions (HPA703XP - (HPA703XP/H)
L1 - WHITE
+ P - RED
L - BLACK
L2 - YE
LLOW
Is recommended to connect the
protection module output serially with
the tamper-preventing contact or to an
“24h” input in the central unit.