ITALIANO 

CARATTERISTICHE TECNICHE 

Alimentazione 

1 pila al litio 3V tipo CR2 

Autonomia 

2 anni (uso normale) 

Portata radio 

oltre 100 m in aria libera 

Trasmissione 
radio 

a modulazione di frequenza 
868 MHz, bidirezionale. 

Elementi di 
segnalazione 

1 LED a 2 colori 

Elementi di 
programmazione 

3 jumper 
1 tasto programmazione/test 

Funzionalità 

periodo di supervisione (90 

110 

min),  segnalazione  pila  bassa, 
tamper 

antiasportazione 

antiapertura 

Ingresso 
ausiliario 

1 per rivelatore tapparella o 
contatto esterno, programmabile 

Dimensioni 
(LxHxP), in mm 

microcontatto: 32x107x22 
magnete: 8x57x11 

 

 

Attenzione:

  prima  di  installare  il 

dispositivo  si  suggerisce  di  effettuare  la  sua 
acquisizione. 

 

 1  POSIZIONAMENTO 

Il microcontatto (

a

) deve essere posizionato: 

 

all’interno dei locali protetti; 

 

sull’infisso  della  porta  o  finestra  (il  magnete 
sull’anta  o  battente),  il  più  lontano  possibile 
dai cardini o dalla cerniere. 

A  porta  o  finestra  chiusa  la  distanza  tra 
DC500  e  magnete  non  deve  superare  i  15 
mm. La posizione del magnete è evidenziata sul 
DC500 da due lineette in rilievo (

b

). 

 

 2  ATTIVAZIONE PILA 

Il  dispositivo  viene  fornito  con  la  pila 
preinstallata

.  Rimuovere  l’isolatore  tirando  la 

linguetta  di  plastica  (

c

)  posta  sul  retro  del 

dispositivo.  Dopo  che  è  stato  alimentato, 
DC500  avvia  la  fase  di  inizializzazione  che 
dura circa 2 minuti. In questa fase il suo LED 
continua  a  lampeggiare  in  Rosso.  Quando  il 
LED  si  spegne  proseguire  con  la  fase  di 
acquisizione. 

 

Attenzione:

  Le  pile  al  litio  esaurite  sono  rifiuti 

speciali  e  devono  essere  smaltite  secondo  le 
disposizioni di legge. 

 

 3  METODI DI INSTALLAZIONE 

Il DC500 viene installato fissandolo con le viti 
fornite,  che  passano  attraverso  i  fori 
predisposti  (

d

).  Chiudere  poi  i  fori  coi  tappini 

di  plastica  bianca  forniti.  Il  magnete  può 
essere  installato  sia  con  le  viti  sia  con  la 
striscia biadesiva fornite. 

 

 4  INGRESSO AUSILIARIO 

Sull’ingresso ausiliario (

e

) è possibile collegare 

un  rivelatore  per  tapparella  o  un  contatto  NC 
(normalmente  chiuso).  Il  jumper  JP3  deve 
essere  impostato  in  accordo  col  dispositivo 
collegato. Aprire il DC500  e sfondare il  guscio 
in  vicinanza  della  morsettiera  per  consentire  il 
passaggio del cavo. La lunghezza del cavo di 
collegamento non deve superare i 10 metri. 

 

 5  CONFIGURAZIONE 

Configurare il dispositivo coi jumper. 
JP1 

Allarme sensore tapparella: 

ON

 = dopo 8 impulsi in 10 secondi 

OFF

 = dopo 5 impulsi in 10 secondi 

JP2 

ON

 = contatto interno disabilitato 

OFF

 = contatto interno abilitato 

JP3 

Tipo ingresso ausiliario: 

ON

 = Rivelatore tapparella 

OFF

  =  Contatto  NC  o  non  utilizzo 

dell’ingresso ausiliario 

Per  le  configurazioni  di  fabbrica  vedere  il 
manuale dell’unità di controllo. 

 

 6  SEGNALAZIONI 

Nella condizione di normale funzionamento, in 
occasione  della  trasmissione,  il  LED  /  tasto  di 
programmazione (figura 

 1 

 f) rimane spento.  

Qualora,  in  occasione  della  trasmissione,  il 
LED si accenda rosso e poi verde, indica : 

 

che la carica della pila è bassa, 

 

l’apertura del tamper, 

 

che il dispositivo è in Test mode (3 minuti). 

 

 7  ACQUISIZIONE DEL DISPOSITIVO 

Acquisire  il  dispositivo  come  illustrato  nel 
manuale  di  installazione  dell’unità  di 
controllo. 

 

 

Nota: 

si  segnala  che  il  Rivelatore  Rottura 

vetri  Elkron 

GD05PL

  può  essere  utilizzato 

collegato  come  contatto  filare,  mentre  il 
sensore  sismico  Elkron 

VSD3

  può  essere 

collegato  come  un  sensore  di  sollevamento 
tapparella. 

 

ENGLISH 

TECHNICAL CHARACTERISTICS 

Power supply 

1 type CR2 3V lithium cell 

Duration 

2 years (normal use) 

Radio range 

over 100 m in free air 

Radio 
transmission 

with frequency modulation 
868 MHz, bi-directional. 

Warning 
elements 

1 2-colour LED 

Programming 
elements 

3 jumpers 
1 programming /test key 

Functionalities 

supervision  period  (90 

110 

min),  low  cell  warning,  anti-
tampering 

protection 

against 

removal and opening, 

Auxiliary input 

1  programmable  auxiliary input for 
rolling shutter or external contact  

Dimensions 
(WxHxD) in mm 

micro contact: 32x107x22 
magnet: 8x57x11 

 

 

Caution:

 before installing the device, it is 

suggested to perform device acquisition. 

 

 1  LOCATION 

Micro contact (

a

) must be located: 

  inside protected rooms; 

  on door or window fixture (the magnet on the 

shutter or leaf), as far as possible from pintles 
or hinges. 

With  the  door  or  window  closed,  the  distance 
between DC500 and magnet must not exceed 
15  mm.  Magnet  position  is  highlighted  on 
DC500 by two raised marks (

b

). 

 

 2  CELL ACTIVATION 

The  device  is  equipped  with  a  pre-installed 
cell. Remove the isolator by pulling plastic tag 
(

c

)  that  is  placed  on  the  rear  side  of  the 

device.  After  being  powered  on,  the  device 
starts  an  initialization  phase  that  lasts  about 
two  minutes.  During  this  phase,  its  LED 
continues  to  flash  red.  When  the  LED  is  off, 
you can continue with the acquisition phase. 

 

Caution:

  Exhausted  lithium  cells  are  special 

waste and must be disposed of according to law 
provisions. 

 

 3  INSTALLATION METHODS 

DC500  is  installed  by  fixing  it  with  provided 
screws,  which  pass  through  prearranged 
holes (

d

). Then close the holes with provided 

white plastic caps. 
The  magnet  can  be  installed  with  both 
provided  screws  and  provided  strap  sticking 
on two sides. 

 

 4  AUXILIARY INPUT 

On auxiliary input (

e

), both a detector for rolling 

shutter or an NC (normally closed) contact can 
be  connected.  Jumper  JP3  must  be  set 
according  to  device  connected.  Open  DC500 
and  break  the  shell  in  the  vicinity  of  terminal 
box to allow cable  passage. Connection cable 
length must not exceed 10 metres. 

 

 5  CONFIGURATION 

Configure the device with the jumpers. 
JP1 

Rolling shutter detector alarm: 

ON

 = after 8 pulses in 10 seconds 

OFF

 = after 5 pulses in 10 seconds 

JP2 

ON

 = internal contact disabled 

OFF

 = internal contact enabled 

JP3 

Auxiliary input type: 

ON

 = Rolling shutter detector 

OFF

 = NC contact or non-use Auxiliary 

input type 

For factory settings see control panel manual. 

 

 6  WARNINGS 

In  normal  operation  condition,  on  transmission, 
programming LED / key (figure 

 1 

 f) remains off.  

Where, on transmission, the LED goes on red 
and then green, it indicates that: 

 

the cell is low, 

 

anti-tampering protection is open, 

 

the device is in Test mode (3 minutes). 

 

 7  DEVICE ACQUISITION 

Acquire the device as illustrated in control unit 
installation manual. 

 

Importantly:

  the  Elkron  glass  breakage 

detector 

GD05PL

 may be used as wired contact 

while  the  Elkron  seismic  sensor 

VSD3

  may  be 

connected as roller opening sensor

.

 

 

 

FRANCAIS 

CARACTERISTIQUES TECHNIQUES 

Alimentation 

1 pile au lithium 3V type CR2 

Autonomie 

2 ans (utilisation normale) 

Portée radio 

Plus de 100 m  en champ libre 

Transmission 
radio 

à modulation de fréquence  
868 MHz, bidirectionnelle. 

Éléments 
d’indication 

1 LED à 2 couleurs 

Éléments de 
programmation 

3 cavaliers 
1 touche programmation /test 

Fonctionnalité 

Période de supervision (90 

110 

min), 

indication 

pile 

basse, 

autoprotection à l’arrachement et 
à l’ouverture 

Entrée auxiliaire   1 programmable pour détecteur 

volet roulant ou contact externe 

Dimensions 
(LxHxP), en mm 

Microcontact: 32x107x22 
aimant : 8x57x11 

 

 

Attention :

 

Avant d’installer le dispositif il 

est conseillé d’effectuer son apprentissage. 

 

 1  POSITIONNEMENT 

Le microcontact (

a

) doit être placé : 

 

À l’intérieur des locaux protégés ; 

  Sur  le  bâti  de  la  porte  ou  de  la  fenêtre 

(l’aimant sur la porte ou battant), le plus loin 
possible des gonds ou de la charnière. 

La  porte  ou  la  fenêtre  fermée  la  distance 
entre  DC500  et aimant ne  doit pas  dépasser 
15 mm. 

La position de l’aimant est  indiquée sur 

le microcontact par deux petites lignes en relief (

b

). 

 

 2  MISE EN SERVICE PILE 

Le dispositif est fourni avec la pile préinstallée. 
Enlever  l’isolateur  en  tirant  la  languette  en 
plastique  (

c

)  placée  sur  la  partie  arrière  du 

dispositif. Après avoir  été mis sous tension,  le 
dispositif  commence  une  phase  d'initialisation 
qui  dure  environ  deux  minutes.  Pendant  cette 
phase,  la  LED  continue  à  clignoter  en  rouge. 
Lorsque  le  voyant  est  éteint,  vous  pouvez 
continuer avec la phase d'acquisition.  

Attention

 

:

  Les  piles  au  lithium  épuisées  sont 

des déchets spéciaux et doivent  être éliminées 
selon les dispositions de la loi en vigueur. 

 

 3  METHODES D'INSTALLATION 

Le DC500 est installé en le  fixant avec  les vis 
fournies,  qui  passent  à  travers  les  trous 
prédisposés (

d

). Fermer ensuite les trous avec 

des petits bouchons en plastique blanc fournis. 
L’aimant peut être installé à la fois avec les vis 
et avec la bande bi-adhésive fournies. 

 

 4  ENTREE AUXILIAIRE 

Sur  l’entrée  auxiliaire  (

e

)  il  est  possible  de 

raccorder un détecteur pour volet roulant ou un 
contact  NC  (normalement  fermé).  Le  cavalier 
JP3  doit  être  configuré  en  accord  avec  le 
dispositif  raccordé.  Ouvrir  le  DC500  et 
défoncer  le  boîtier  à  proximité  de  la  plaque  à 
bornes pour permettre le passage du câble. La 
longueur  du  câble  de  raccordement  ne  doit 
pas dépasser 10 mètres. 

 

 5  CONFIGURATION  

Configurer le dispositif avec les connecteurs. 
JP1 

Alarme détecteur volet roulant: 

ON

=après 8 impulsions en 10 secondes 

OFF

 = après 5 impulsions en 10 secondes 

JP2 

ON

 = contact interne désactivé  

OFF

 = contact interne activé  

JP3 

Type entrée auxiliaire: 

ON

 = Détecteur volet roulant 

OFF

  =  Contact  NC  ou  non-utilisation 

Type entrée auxiliaire 

Pour  les  configurations  d'usine  voir  le  manuel 
de l'unité de contrôle. 

 

 6  INDICATIONS 

Dans la condition de fonctionnement normal, à 
l’occasion de la transmission, la  LED /  touche 
de programmation (figure 

 1 

  f) reste éteinte.  

Au cas où, à l’occasion de la transmission, la LED 
s’allume au rouge et ensuite au vert, elle indique : 

 

que la pile est basse, 

 

l’ouverture du de l’autoprotection, 

 

que le dispositif est en Test mode (3 minutes). 

 

 7  APPRENTISSAGE DU DISPOSITIF 

Effectuer l'apprentissage du dispositif comme 
illustré  dans  le  manuel  de  l’installation  de 
l’unité de contrôle. 

 

Note : 

A noter que le détecteur de bris de vitre 

Elkron 

GD05PL

  peut  être  utilisé  raccordé 

comme  un  contact  filaire,  tandis  que  le 
détecteur  sismique  Elkron  VSD3    peut  être 
raccordé  comme  un  détecteur  d’ouverture  de 
volet roulant

.

 

DS

8

0

M

M

0

5

-0

0

1

E

   

  

L

B

T

8

0

6

5

7

 

Made in TAIWAN 

Отзывы: