background image

(((ELKRON))) - CT10-M / CT11-M

1 7

• Various devices can be switched on and off remotely (e.g. air conditioner, lights, irriga-

tion system, etc.) by sending DTMF commands to any telephone and switching the

communicator outputs which are programmed as 

remotely controllable 

(U3, U4,

U5). If enabled, the communicator will answer incoming calls at any time, except for

when it is making alarm calls. To remotely control a device, call the CT10-M/CT11-M

GSM  number or PSTN number (CT11-M only) and wait for an answer. GSM calls will be

answered after at least six rings (heard by the caller). PSTN calls will be answered after

a programmable number of rings (2-4-8, see paragraph 8.4).

• Answers are notified by a tone allowing the caller to dial the USER CODE (in DTMF)

within 30 seconds. A confirmation tone will be heard after each digit. A sequence of

three confirmation tones will be heard at the end of the code if the code is correct.

Otherwise a long error tone will be heard. Three attempts to enter the correct code can

be made before the call is ended.

• The remote control can be used to switch the required outputs (see sequence in the

following figure) after the code has been accepted. This operation requires a three-digit

code:

- 5: defines the type of “output switching” command.

- 3 or 4 or 5: defines the output number to be switched

- 1 or 0 is used to activate or deactivate the required output.

The communicator will give priority to an alarm triggered during the remote control

procedure. No on/off commands will be accepted and a WRONG CODE BEEP will be

output. Hang up.

• Each remotely controllable output can be programmed as maintained or timed.

- Status changes follow the command if the output is maintained.

- The on command (1) will activate the output and the timer while the off command

(0) will anticipate the time-out (if this has not already occurred) if the output is timed.

• The user has one minute from code recognition to complete the remote control opera-

tions. If no codes are sent by this time-out, the communicator will end the call in

progress and clear the line.

• The communicator will send a short confirmation tone after receiving each remote

control. A longer tone will be heard in the case of the following errors:

- programmed output other than “remotely programmable”

- wrong code

• If the code is accepted, the communicator will send the voice message recorded by the

user to confirm implementation of the control.

At this point, the user will need to enter the “5” code again to switch other

outputs (or the same output) at the end of the voice message

NOTE: You are advised to deactivate the “ANSWERING SERVICE” function provided

by the GSM operator.

• SKIP ANSWERING MACHINE MESSAGE (CT11-M only)

Connect to the communicator as follows if an answering machine is fitted on the PSTN

line used by the CT11-M:

- call the PSTN  telephone number

- wait for a single ring tone

- hang up quickly

- call the number again

5. 0Answering service and remote control

function

Содержание CT10-M

Страница 1: ...IS0171 AA 07 2003 CT10 M GSM telephone communicator CT11 M GSM PSTN telephone communicator User manual ...

Страница 2: ...sage editor menu 13 3 10 Voice message programming menu 15 4 0 Cycle call stopping 15 5 0 Answering machine e remote control 16 Alfanumeric coding table 19 DIRECTIVE R TTE 99 05 EC COMPLIANCE Informative note Ministerial type approval for transceivers and telecommunication terminals was abolished on 8 April 2000 The CT11 M terminal is designed and certified for PSTN Public Switched Telephone Netwo...

Страница 3: ...FAST BLINKING TRANSMITTING 1 2 DESCRIPTION OF THE KEYS OK key used to confirm parameter modifications during programming and to start listening to and recoding messages Arrow keys used to scroll the programming menu and select the functions to be programmed EXIT key used to quit the programming menus Number pad keys for entering access code telephone numbers and selecting programming parameter val...

Страница 4: ... AND NETWORK BATTERY FAILURE WARNING LEDS 2 2 VIEWING SYSTEM STATUS The SYSTEM STATUS menu can be accessed in any condition without entering a code Simply press C followed by a number key from 1 to 8 Either press to quit the menu or wait for the time out one minute IN Not QUITTED IN 1 alarm memory IN 2 alarm memORY IN BUTTONS TO PRESS LANGUAGE FRENCH GERMAN DISPLAY TRANSMETTEUR GSM RTC COMMUNICATO...

Страница 5: ...ATION IF ANOMALY PRESENT WARNING CT11 M only CYCLES WITH ANOMALIES TOTAL CYCLES CALLS WITH ANOMALIES GSM CALLS MADE CALLS WITH ANOMALIES PSTN CALLS MADE NUMBER OF NO FIELD COVERAGE FAILURES N OF DISCONNECTION FAILURES BETWEEN GSM MODULE AND CT10 M CT11 M OR MISSING SIM CARD NUMBER OF NO PSTN LINE FAILURES CT11 M COUNTER RESET COMMAND ACTIVE ONLY WHEN FAILURE AND ANOMALY CONDITIONS HAVE BEEN RESTOR...

Страница 6: ...de because the system is being supervised at the time 3 1 USER PROGRAMMING LIST Enter the 6 digit user code x x x x x x default 111111 USER MENU TELEPHONE NR USER MENU SWITCH OUTPUT USER MENU CODE CHANGING USER MENU CALL TEST USER MENU SMS MESSAGE USER MENU VOCAL MESSAGES USER MENU ANSWERING PROG USER MENU ENGINEER ENABLED USER MENU SIM CARD 6 7 11 12 14 pag pag pag pag pag 8 pag 10 pag 9 pag 8 pa...

Страница 7: ... 9 to enter the required telephone number digits Press to include a 2 seconds pause during dialling To edit a telephone number position the cursor on the digit to be changed by pressing and enter the new digits Press C to delete the entire number Press 0 for at least one second to enter the international prefix CT10 M only Press 7 PQRS for at least one second to enter Press 9 WXYZ for at least one...

Страница 8: ... to its original condition to select the outputs to confirm the output to switch to return to the output switching menu to confirm the selection The current output status is displayed Press C to change user MENU SWITCH OUTPUT SWITCH OUTPUT OUTPUT NR 3 SWITCH OUTPUT OUTPUT NR 4 SWITCH OUTPUT OUTPUT NR 5 OUTPUT NR 5 DISABLED OUTPUT NR 5 ENABLED SWITCH OUTPUT OUTPUT NR 5 ...

Страница 9: ...NU for remote controls This procedure can be used to activate the answering service function permitting a connection between the caller and the communicator to operate remote controls to confirm The answering service function will be activated also if the skip outgoing message is automatically activated The number of rings on CM10 M are only indicative USER MENU ANSWERING PROG ANSWERING PROG OFF A...

Страница 10: ... customise the USER access code default 111111 to confirm the entered code Enter the new 6 digit programming code by means of the number keys 0 9 Re enter the new code by means of the number keys 0 9 to reconfirm the entered code USER MENU CODE CHANGING NEW CODE NEW CODE CODE CONFIRM ...

Страница 11: ...d before programming the SIM card expiration ENGINEER MENU SIM CARD SIM CARD EXPIRE mm aa to confirm Enter the 4 digits corresponding to the month and year of expiration by means of the numeric keys 0 9 You are advised to enter the month before that of actual expiration of the SIM card SIM CARD EXPIRE 03 04 EXAMPLE EXAMPLE SIM CARD EXPIRATION MARCH 2004 The SIM card expiration text message will be...

Страница 12: ...ling 12 in DTMF from the telephone which is receiving the call The test call will not be made if the 12th telephone number is not programmed CT11 Monly to select the telephone network Press the communciator will make one call to the 12th number repeating the basic voice message three times The test call cycle can be barred by entering dial 12 in DTMF from the telephone which is receiving the call ...

Страница 13: ...IRATION WARNING CT10 M SIM CARD EXPIRATION The message text for each ALARM FAILURE SIM CARD EXPIRATION event can be freely edited maximum 40 characters per message to select actions to confirm selection to confirm message selection to select messages Enter the number by means of the number keys 2 9 by pressing the button corresponding to one two three or four times according to the position of the...

Страница 14: ...HAN 16 CHARACTERS An arrow will appear after the last character if the message is more than 16 characters long Press and to see the rest of the message Reading a text message Deleting a text message READING SMS 02 READING SMS 03 READING SMS 04 FALLING sim CT10 M MESSAGE SMS READING SMS READING SMS 01 CANCEL SMS 01 CANCEL SMS 02 CANCEL SMS 03 CANCEL SMS 104 FALLING sim CT10 M MESSAGE SMS DELETE SMS...

Страница 15: ...nput 2 alarm 5 sec Output U3 on 5 sec Output U3 off 5 sec Output U4 on 5 sec Output U4 off 5 sec Output U5 on 5 sec Output U5 off 5 sec TECHNICAL FAILURE 5 sec TELEPHONE FAILURE CT11 M only 5 sec Scroll the list and select the message to be recorded or played to confirm the selection Press to start recording The remaining time will decrease on the display EXAMPLE to confirm selection USER MENU VOC...

Страница 16: ...the call cycle in progress is barred when the TC switched to ON The call cycle can also be barred locally by means of the keypad by entering a valid code user code or ENGINEER code where enabled BASIC MESSAGE SPECIFIC MESSAGE BEEP WAIT FOR BARRING BASIC MESSAGE SPECIFIC MESSAGE BEEP WAIT FOR BARRING BASIC MESSAGE SPECIFIC MESSAGE BEEP WAIT FOR BARRING 10 s 5 s 0 5 s 5 s 10 s 5 s 0 5 s 5 s 10 s 5 s...

Страница 17: ...utput The communicator will give priority to an alarm triggered during the remote control procedure No on off commands will be accepted and a WRONG CODE BEEP will be output Hang up Each remotely controllable output can be programmed as maintained or timed Status changes follow the command if the output is maintained The on command 1 will activate the output and the timer while the off command 0 wi...

Страница 18: ...CODE RECEIVED CODE DIGIT RECEIVED CODE DIGIT RECEIVED CODE DIGIT RECEIVED CODE DIGIT RECEIVED CODE DIGIT BEEEEP WRONG CODE 1 2 5 RECEIVED 0 5s BEEP Send code 5 3 3 Send code corresponding to output to be switched OR OR repeatprocedurefrompoint 2 RECEIVED 0 5s BEEP 4 4 5 OR 0 Send code 1 on or 0 off 5 1 OR 0 5s 3BEEPS COMMAND DONE ASSOCIATED VOICE MESSAGE More than one output can be switched or the...

Страница 19: ...11 M 1 9 ALPHANUMERIC CODING TABLE T U V 8 1 2 ABC 3 DEF 4 GHI 5 JKL 6 MNO 7 PQRS 8 TUV 9 WXYZ Ø 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 P Q R S W X Y Z 7 9 KEY NUMBER OF TIME TO PRESS KEY 1 2 3 4 5 6 7 8 WHITESPACE 0 ...

Страница 20: ... CT11 M 2 0 ELKRON SPA Via Carducci 3 10092 BEINASCO TO TEL 011 3986711 FAX 011 3499434 EMAIL info elkron it EMAIL Assistenza Tecnica stac elkron it UNI EN ISO9001 UNI EN ISO14001 CERTIFICAZIONI DI QUALITA AZIENDALE ...

Отзывы: