RFSAI-11B-SL

230 V AC

50-60 Hz

7 VA / cos

 φ 

= 0.1 / 0.7 W

1x switching contacts (AgSnO

2

)

8 A / AC1 / 2000 VA

10 A / <3 s

250 V AC1

button PROG (ON/OFF)

868.5 MHz

-15 ... + 50 °C (5 ... 122 °F)

free at lead-in wires

IP40

III.

43 x 44 x 22 mm (1.9“ x 1.97“ x 0.8“)

31 g

EN 60730, EN 63044, EN 300 220, EN 301 489

Supply voltage:

Supply voltage frequency:

Power apparent / dissipated:

Output:

Number of contacts:

Rated current: / switching power

Peak current:

Max. switching voltage:

Communation:

Manual:

Frequency:

Other data:

Operating temperature:

Mounting:

Protection:

Overvoltage category:

Dimensions:

Weight:

Related standards:

Technical parameters

Содержание RFWB-20/G

Страница 1: ...SS SWITCH CLASSIC VERSION Combination of iNELS wall mounted wireless controller and switching unit for various uses It can be used to remote control electrical appliances lights sockets garage doors e...

Страница 2: ...ndividual elements in the iNELS kit are paired and their functions are preset iNELS kit wireless switch enables the basic function of controlling electrical appliances ON OFF The settings of the wall...

Страница 3: ...box RFWB 20 G On wall button controller PLASTIC 2 buttons RFWB 40 G On wall button controller PLASTIC 4 buttons Safe handling Battery replacement RFWB 20 RFWB 40 Using a screwdriver carefully pry off...

Страница 4: ...ns Transmitter frequency Signal transmission method Range in free space Other data Operating temperature Operating position Mounting Protection Contamination degree Dimensions Weight Related standards...

Страница 5: ...nit can be controlled by up to 25 channels 1 channel represents one button on the controller The programming button on the unit is also used for manual control of the output Memory status can be pre s...

Страница 6: ...x 44 x 22 mm 1 9 x 1 97 x 0 8 31 g EN 60730 EN 63044 EN 300 220 EN 301 489 Supply voltage Supply voltage frequency Power apparent dissipated Output Number of contacts Rated current switching power Pe...

Страница 7: ...ice can be combined with devices of iNELS RF Control2 with RFIO2 protocol Connection Screwless terminals S external input N neutral wire L phase wire V output i programing button manual controll outpu...

Страница 8: ...case you notice any sign of damage deformation malfunction or missing part do not install this device and return it to its seller It is necessary to treat this product and its parts as electronic wast...

Отзывы: