1. Using a Phillips head screwdriver, remove the screw on the back of the transmitter. 

Remove the rear cover.

2. Carefully remove the device from the box.
3. Slide the CR2032 battery into the battery holder. Observe the polarity.
4. Insert the device into the housing so that it clicks onto the tabs and to the stops inside 

the housing. 

5. Replace the rear cover and replace the screw.

Notice:
Only use batteries designed for this product correctly inserted in the device! Immediately replace 
weak batteries with new ones. Do not use new and used batteries together. If necessary, clean the 
battery and contacts prior to using. Avoid  battery  shorts!  Do not dispose of batteries in water or 
fi re. Do not dismantle batteries, do not try to charge them and protect them from extreme heating 
- danger of leakage! Upon contact with acid, immediately rinse the aff ected area with a stream of 
water and seek medical attention. Keep batteries out of the reach of children.  If it is suspected that 
the battery has been swallowed or somehow placed inside the body, consult a doctor immediately.  
Give the doctor  information about the type of battery (from battery case, device or its manual, etc.) 
to determine the chemical composition of the battery. Batteries must be recycled or returned to an 
appropriate location (e.g. collection container) in accordance with local legal provisions.

Programming the controller for the detector

1. Push the screwdriver into the opening at the top of the detector and open the device 

cover.

2. Remove the original battery and insert new batteries into the battery holder. Beware 

of polarity. The blue LED on the detector will blink.

3. Replace and snap the front cover. 

Insertion and replacement of a battery

Replacing batteries

Assembly AirMD-100

Safe handling

1. Push the screwdriver into the opening at the top of the detector and open the device 

cover.

2. You can attach the product either by sticking * on a fl at surface - apply a suitable adhe-

sive to the outside of the base. Place the base in the desired location and let it dry.

3. Or using a suitable fastener ** by screwing. 

a) Push the beaks (mouldings) on the setting component down and remove the com-

ponent from the base.

Depending on the required location, remove the screw plugs from the base (e.g. with a 
screwdriver).
b) To place on a fl at surface.
c) To place in a corner.

Place the base at the desired location and attach it with suitable bonding material accor-
ding to the substrate**.
d) On a fl at surface.
e), f ) into a corner.

4. Insert the component into the base and snap into place with pressure, gently. 

5. Program the instrument (see chapter Programming the controller) and adjust the sen-

sitivity of the PIR sensor.

6. Replace and snap the front cover.

Recommendations for installation

• When installing the detector, consider the handling area above the detector (to replace 

the batteries, etc.). Do not exceed the maximum recommended height for placement.

• The detector is intended for indoor use.

• After inserting the battery, the time delay is 15 seconds to stabilize the PIR detector, and 

then the motion detection function is activated.

* The glue must meet the optimal conditions for product placement (infl uence of tem-

perature, humidity ...)

** For example, a countersunk head screw can be used as a suitable fastener, screw of 

max. Ø 3 mm.

When handling a device unboxed it is important to avoid contact with 
liquids. avoid unnecessary contact with the components of the device. Do 
not touch the metal objects inside the unit.

1. Switch DIP3 switch to ON.

2. Press the TAMPER button several times (to discharge the capacitors in the device).

3. Insert the batteries (observe the polarity). The blue LED flashes once every second, the 

detector enters the programming mode.

4. Switch the DIP3 switch to OFF - this will lock the detector in the programming mode.

5. Press one of the control button DISARM ( ) on the controller, the LED on the detector 

indicates blue LEDs with a long flash. This way you can program the desired number 
of controllers.

6.  To  quit  the  programming  mode,  turn  the  DIP3  switch  to  ON  and  then  back  to  OFF. 

The blue LED on the detector will flash a long time. The detector will restart and go 
into operating mode. After approx. 15 seconds (required to stabilize the PIR sensor), it 