Technical parameters

Warning

Before the device is installed and operated, read this instruction manual carefully and with full 
understanding and Installation Guide System iNELS3. The instruction manual is designated for 
mounting the device and for the user of such device. It has to be attached to electro-installation 
documentation. The instruction manual can be also found on a web site www.inels.com. Attention, 
danger of injury by electrical current! Mounting and connection can be done only by a professional 
with an adequate electrical qualifi cation, and all has to be done while observing valid regulations. 
Do not touch parts of the device that are energized. Danger of life-threat! While mounting, 
servicing, executing any changes, and repairing it is essential to observe safety regulations, norms, 
directives and special regulations for working with electrical equipment. Before you start working 
with the device, it is essential to have all wires, connected parts, and terminals de-energized. This 
instruction manual contains only general directions which need to be applied in a particular 
installation. In the course of inspections and maintenance, always check (while de-energized) if 
terminals are tightened.

Inputs

Angle of motion detection:

Recommended installation 

height:

Changing the PIR sensitivity:

PIR scan type:

Default setup PIR:

Temperature measuring:

Scope and accuracy of 

temp. measurement:

Humidity measurement:

Humidity meas. range:

Humidity meas. acc

urancy:

Light Metering:

Detection angle:

Measuring range:

Number of control buttons:

Outputs

Indication red LED:

Indicating blue LED:

Indication green LED RUN:

Communication

Interface:

Power supply

From iNELS BUS:

Rated current:

From DALI BUS:

Rated current:

Connection

Terminals:

Operating conditions

Operating temperature:

Storing temperature:

Protection degree:

Operation position:

Installation:

Dimension and weight

Dimension:

- installation hole diameter:

- diameter visible:

Weight:

140 °, 4 m

2.5 - 3 m

Yes, 0.. 127 (max. sensitivity)

single / dual

99 dual

YES, built-in temperature sensor 

-25.. +110 °C; ± 0.3 °C

YES

0 .. 99% RH

± 4 % RH

YES

± 55 °

1 - 100 000 lx

1

identifi cation DALI MASTER / 

communication options

PIR Activation

communications / unit status 

Installation BUS iNELS DALI

27 V DC, -20 / +10 %

18 mA

16 V (max. 23 V)

27 mA

0.3 - 0.8 mm

2

-20 .. +55 °C

-30 .. +70 °C

IP20

vertical 

celling

Ø 76 x 73 mm

60 mm

76 mm

81 g