Elko iNELS Air AirQS-101 Скачать руководство пользователя страница 5

1 / 4

AirQS-101

02-6/2019 Rev.: 0

1

1

1

8

4

4

4

4

7

2

2

2

2

6

5

3

3

3

ELKO EP, s.r.o. 

Palackého 493
769 01 Holešov, Všetuly
Czech Republic 
Tel.: +420 573 514 211
e-mail: [email protected]
www.elkoep.com

Characteristics 

Description

EN

Made in Czech Republic

Air quality sensor - carbon monoxide (CO)

•  AirQS-101 - is used as a safety device for monitoring the CO concentration resul-

ting from incomplete combustion. It also informs you of the actual temperature, 
humidity and light intensity in the area.

•  Provides a quick solution to learn about undesirable CO concentrations that can 

be immediately reacted too.

•  The self-test function alerts you to a detector malfunction, eliminating its mal-

function.

•  Anti-sabotage: If access to the device is unauthorized, a message is immediately 

sent to the server.

•  Thanks to the wireless solution and Sigfox / LoRa / NB-IoT communication, it can 

communicate instantly to your chosen location and be operated immediately.

•  Data is sent to the server from which it can be subsequently displayed as a smart-

phone, application, or Cloud notifi cation.

•  Battery power can be sent to the server when it is powered by a battery.

•  Power supply: battery 4 x 1.5 V AA, the battery life is around 1 year.

General instrucions

Internet of Things (IoT)

• The IOT wireless communications category describes the Low Power Wide Area 

(LPWA).  This  technology  is  designed  to  provide  full-range  coverage  both  inside  and 
outside buildings, energy-saving and low-cost operation of individual devices. Indivi-
dual networks - Sigfox, LoRa, NarrowBand - are available to use this standard.

Sigfox network information

•  The network supports bidirectional communication but with a limited number of feed-

backs. It uses the free frequency band divided by Radio Frequency Zones (RCZ).

•  RCZ1 (868 MHz) Europe, Oman, South Africa
•  RCZ2 (902 MHz) North America
•  RCZ3 (923 MHz) Japan
•  RCZ4 (920 MHz) South America, Australia, New Zealand, Singapore, Taiwan

•  Sigfox has more coverage across countries, so it is better suited for long distance mo-

nitoring.

•  For more information on this technology, please visit www.sigfox.com.

LoRa network information

•  The network is bidirectional and its communication uses free frequency band.

•  865 - 867 MHz 

India

•  867 - 869 MHz  

Europe

•  902 - 928 MHz 

North America, Japan, Korea

•  The advantage of this network is the possibility of freely deploying individual stations 

in local locations, thus strengthening their signal. It can therefore be used effi

  ciently in 

company premises or, for example, in local parts of cities.

•  For more information on this technology, please visit www.lora-alliance.org.

Information about the NarrowBand network

•  The network provides two-way communication and the only one to use the licensed 

LTE band. Our devices allow band 1 (2100MHz), Band 3 (1800MHz), Band 8 (900MHz), 
Band 5 (850MHz), Band 20 (800MHz) and Band 28 (700MHz).

•  It uses this SIM card technology for each device.
•  The advantage of NarrowBand is the use of already built-up grids, which ensures suffi

  -

cient reception outside and inside buildings.

•  For more information on this technology, please visit www.vodafone.cz

Caution for proper operation:

•  Products are installed according to the wiring diagram given for each product.
•  For proper device functionality, it is necessary to have suffi

  cient coverage of the selec-

ted network at the installation site.

•  At the same time, the device must be registered in the network. Successful device re-

gistration on a given network requires a charge for traffi

  c.

•  Each network off ers diff erent tariff  options - it always depends on the number of me-

ssages you want to send from your device. Information on these tariff s can be found in 
the current version of the ELKO EP pricelist.

Cloud app assignment

It is done in your Smartphone application. Enter the relevant data located on the detec-
tor cover into the application.

1. Two-color LED position
2. Holes for locking segments
3. Battery
4. Secure segments
5. DIP switch - Position 1 - Turn off  

scanning signaling

6. Button SET
7. Tamper position
8. Probe for magnet scanning 

tampermenty

The underside of

the detector

The inner side of

the base

The front of the

detector

Содержание iNELS Air AirQS-101

Страница 1: ...kryt i nap jednotliv mi st ty proto je vhodn j pro moni torov n za zen na velk vzd lenosti V ce informac o t to technologii se dozv te na str nk ch www sigfox com Informace o s ti LoRa S je obousm rn...

Страница 2: ...te bezpe nostn pov dom a dbejte na preventivn opat en aby se zabr nilo nebezpe kdykoli a kdekoli je to nutn Detektor m e sn it pravd podobnost katastrofy ale nedok e zaru it 100 bezpe nost Detailn inf...

Страница 3: ...te zda nikdo ze zasa en ch osob nevykazuje p znaky otravy CO V mnoha p padech otravy CO doch z k tomu e ob ti si uv do muj e se nec t dob e ale st vaj se natolik dezorientovan mi e nejsou schopny se s...

Страница 4: ...ad s kovov mi dve mi znemo n se t m prostupnost radiofrekven n ho sign lu iNELS Air se nedoporu uje pro ovl d n p stroj zaji uj c ch ivotn funkce nebo pro ovl d n rizikov ch za zen jako jsou nap erpad...

Страница 5: ...s so it is better suited for long distance mo nitoring For more information on this technology please visit www sigfox com LoRa network information The network is bidirectional and its communication u...

Страница 6: ...ial dangers develop safety awareness and take precautions to avoid dangers whenever and wherever needed The detector can reduce the likeli hood of catastrophe but cannot guarantee 100 safety Detailed...

Страница 7: ...f fresh air Ensure that all persons have left the area Check that none of the affected persons have signs of CO poisoning In many cases CO poisoning causes victims to realize that they do not feel wel...

Страница 8: ...gnated for mounting and also for user of the device It is always a part of its packing Installation and connection can be carried out only by a per son with adequate professional qualification upon un...

Отзывы: