Activating the display
Pressing an operating key activates the display.
The display lights up and the most recently set overtravel
time
A
is displayed.
At the time of the first activation, "--" (overtravel time not
activated) is displayed.
Setting the overtravel time
1
Alter the overtravel time:
a) In steps by briefly pressing "+" or "-" repeatedly
or
b) Steplessly by pressing and holding down either
"+" or "-"
The overtravel time displayed flashes for as long as you
continue to actuate the operating keys
A
.
2
Complete your input with the desired overtravel
time.
If no input takes place within three seconds, the overtrav-
el time will start up automatically. The load is switched
on.
The status display
B
flashes while the overtravel time
A
is running down step-by-step.
|
You can change the value of the overtravel time
even when the overtravel time is activated. The
load remains switched on for as long as the over-
travel time displayed is greater than 0.
Ending the overtravel time
Once the overtravel time has expired, the load is auto-
matically switched off. The display switches into OFF
status (dimmed, overtravel time "--").
To switch off the load before expiration of the overtravel
time, set the overtravel time to "--".
Operating the timer via external push-button
The timer can be operated via an externally connected
mechanical push-button. This function is disabled by de-
fault. Activate the desired function of the external push-
button in the settings menu (see chapter "Changing set-
tings").
• Trigger function (ON): Pressing the external push-but-
ton starts the most recently set overtravel time. An al-
ready activated overtravel time is restarted.
The activated overtravel time cannot be ended with
the external push-button in this mode.
• Toggling function (OFF): Pressing the external push-
button starts one of two functions in rotation. The first
time the external push-button is pressed, the most re-
cently set overtravel time is started. The next time it is
pressed, the overtravel time is ended and the load is
switched off.
|
After an external signal input, the timer disables
for 2 seconds.
Operating the timer
A
A
B
A
Changing settings
The maximum and minimum overtravel time and function
of the external push-button can be changed:
• Minimum overtravel time (LO):
1 Minute (01.) to 8 hours (8.0)
Default: 1 minute (01.)
• Maximum overtravel time (HI):
minimum overtravel time up to 8 hours (8.0)
Default: 4 hours (4.0)
• Function of external push-buttons (Input):
disabled (--), Trigger (ON), Toggle (OFF)
Default: disabled (--)
Adjust the settings one after the other.
|
The menu is exited automatically if no input in the
settings menu takes place within one minute.
Changes that have been made are saved.
1
Hold down "+" and "-" together for three seconds to
enter the settings menu.
2
Press "+" or "-" to change the setting that is dis-
played.
3
Press "+" or "-" simultaneously to confirm the input
and to switch to the next setting.
The menu is exited automatically when the last setting is
confirmed.
Error messages on the display
Connected load does not switch on:
• Observe the message on the display:
Switch timer off and back on again with "Error HEAt".
If the error message "Error HEAt” recurs, have cause
of error investigated by a specialist.
• Check the power supply.
• Switch the timer off and back on again.
• Check the load.
• Check wiring with external push-button.
No message on the display
:
• Check the power supply.
• Switch the timer off and back on again.
What should I do if there is a problem?
Display
Meaning
Internal overheating of the timer
Error Heat
ELKO AS, Sandstuveien 68, 0680 Oslo
Phone.: +47 67 80 73 00 - E-mail: [email protected]
Pb. 6598 Etterstad, 0607 Oslo
www.elko.no
Technical data
Nominal voltage:
230 V AC, 50 Hz
Nominal load (ohmic):
16 A
Nominal load (inductive):
1 A, cos
φ
= 0.6
Switching capacity:
Ohmic load:
3600 W
Fluorescent lamps with electron-
ic ballasts:
35
μ
F
LV halogen lamps with wound or
electronic transformer:
1000 VA
Motors:
500 VA
230 V halogen lamps:
1000 W
LED lamps:
100 W
Switch:
2-pole
Relay:
1-pole, 16 A
Adjustable overtravel time
1, 2, 3, ...20 min
30, 40, ...50 min
1, 1.5, 2, ...8 h
Type of housing protection:
IP 20
Rated surge voltage:
4 kV
Connecting terminals:
max. 2.5 mm²
Operating temperature:
-10°C to +35°C
Overvoltage/
overheating protection:
electronic
Accuracy of time specification:
+/- 1.5%