Receiver DCF 77
•
universal DCF module, intended to control time switch SHT-6, or other devices
•
suitable for outdoor use (IP65 protection)
•
two wire connection - not depends on polarity!
•
cable lengths of up to 100 meters
•
optical indication of proper module function
Characteristics
Description
Connection with SHT-6
EN
Warning
Connection:
Max. conductor cross-section:
Max. voltage on the wires:
Indicator functions:
Other information
Storage temperature:
Protection degree:
Dimensions:
Weight:
Operating position:
Service area:
2 conductors
2.5 mm
2
10 V
red LED
-30.. +70 °C (-22.. 158 °F)
IP65
98 x 62 x 34 mm (3.85“ x 2.44“ x 1.34“)
110 g (3.88 oz)
perpendicular to the direction of reception
about 1500 km from Frankfurt / Main
Technical parameters
Installation and connection should only be carried out by a qualifi ed installer or electrician,
who is thoroughly familiar with these instructions and functions of device. Before starting
the installation, please make sure that the device is de-energized and the main switch is
in the off position. For installation and setting use screw-driver cca 2 mm. The device is
fully-electronic - installation should be carried out according to this fact. Non-problematic
function depends also on the way of transportation, storing and handling. In case of any
signs of destruction, deformation, non-function or missing part, don´t install and claim
at your seller it is possible to dismount the device after its lifetime, recycle, or store in
protective dump.
connection
with SHT-6
(max. 100 m)
In case of using shielded cable it is necessary to connect the shield to terminal G.
Installation
income (input) direction
For mounting DCFR-1 is necessary
to choose an appropriate place in
the open air, best on the façade
or under the roof, remember
to maintain the right direction
regardless of signal reception.
DCFR-1 needs to be installed as
far as possible from the following
devices (at least 3 m):
- metal construction
- electrical switchboards
- TV receivers, monitors, laptops
- radio broadcasting and other
similar devices
WARNING: DCFR-1 is electrically
connected to the power supply
circuits SHT-6 - it is necessary
to provide adequate insulation
coverage when installing the
service cable.
Function
DCFR-1 is designed to receive and decode the signal DCF-77. The correct operation is
indicated by the red LED fl ashing at interval 1s.