![ELKHART BRASS Copperhead RF 8593-04 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/elkhart-brass/copperhead-rf-8593-04/copperhead-rf-8593-04_installation-operating-and-maintenance-instructions_2393091011.webp)
12
Installation Step 3: Program Settings
RF Receiver/Control Module Settings –
The SW1 switch is used for choosing the monitor programming. The SW4 switch has been factory
preset for position “E”. This setting allows for slow horizontal travel for the first 2-3 seconds before
switching to full speed. Changing to setting “8” allows full speed at all times (see Table 3, reference 4
on page 16).
This monitor has been equipped with mechanical hard-stops to prevent horizontal over-travel (see
Installation Step 4: System Programming). The hard-stops are permanently fixed by a stop screw and
milled slot in the base. Follow the programming steps to set all travel limits as prescribed in Installation
Step 4.
NOTE: The horizontal limits must be set to stop the motors at the location of the hard-stops.
E
8593-04 Copperhead RF – Blinking – Stow Indicator & Slow Start-up
8
8593-04 Copperhead RF – Fast Start-up
NOTE: When setting is changed power to the monitor must be cycled OFF/ON.
If it is set to a value that is not yet programmed, the status indicator LED, DS5 (see Figure 1), will blink
rapidly until a valid setting is selected
AND
power is cycled. If SW4 is set to a valid setting but not one
of the above positions, unpredictable results will occur.
DS2
DS4
DS3
Status LED
SW1 DS1
SW3
B
P3
A
SW2
DS5
P4
P2
DS6
SW4
SW4
Figure 1: RF Receiver/Control Module Circuit Board
P1