15
EXM2 Wiring Connections (Shown with all Elkhart Brass Provided harnessing)
EXM2 Monitor
7051X2 EXM2 Position
Feedback Module
Terminating
Resister
7010X2 EXM2 Panel Mount
or
7030X2 EXM2 Joystick Controller
(Both Factory Set as Primary)
EXM2 Gateway
EXM2 Handheld Controller
and Docking Station
E14X/E16X
Actuated Valve
Valve comes terminated
from factory
7015X2 EXM2
Handheld Package
(Factory Set as Secondary)
EXM2 monitors come terminated
from factory and should
always be at end of CAN line
Items can be installed in any order
Example of an EXM2 System with a terminated valve at opposite end of main CAN line
(This system does not require configuration)
F
CAN Splitter
F
CAN Splitter
F
CAN Splitter
E
E
E
E
B
A
A
J
C
Panel Mount Controller
• Using the Panel Mount Controller template located at www.elkhartbrass.com,
drill 6 #7(0.201" 5.1mm) holes as shown through the panel.
• The device should be mounted in the vehicle such that a minimum separation
distance of 7.9" (20 cm) is maintained between the device (and/or its antenna)
and any persons during normal operation .
• Mount the controller with six (6) 10-24 screws using blue Loctite 242 or
equivalent. The controller has a 0.375 thread depth. Torque screws to 50-60 in-
lbs (5.6-6.8 Nm).
• Connect plug 1 to the CAN line.
• Supply power to the controller by connecting plug 2 leads to an appropriate
power source. Red (+) and black (-).
• Install a 1 Amp fuse into the positive (red +) power lead for a 12V system (1/2
Amp for 24V system).
• Termination requires CAN splitter (P/N 24196000) and CAN termination plug
(P/N 24197000) not included. Non-termination requires CAN splitter (P/N
24196000) not included.
• Refer to the respective plug figures for information on the plugs’ pins.
1
2