Elkay VRCTLFR Series Скачать руководство пользователя страница 3

98220C  (2/06)

VRCTLFR8*1A

Page 3

Stainless Steel

PANEL COLOR

COLOR TABLE

Item No. 37

Part No.

Item No. 32

Part No.

Item No. 33

Part No.

Item No. 34

Part No.

Item No. 35

Part No.

Item No. 36

Part No.

28525C

28519C

28516C

28536C

28522C

22955C

Refrig. Unit

Stainless Steel

PANEL COLOR

COLOR TABLE

Item No. 37

Part No.

Item No. 32

Part No.

Item No. 33

Part No.

Item No. 34

Part No.

Item No. 35

Part No.

Item No. 36

Part No.

28539C

28519C

28516C

28528C

28522C

22955C

Left Unit

IMPORTANT

ALL SERVICE TO BE PERFORMED BY

AN AUTHORIZED SERVICE PERSON

HANGER BRACKETS & TRAP

INSTALLATION

1) Remove hanger bracket fastened to back of cooler by removing one (1)

screw.

2) Mount the hanger bracket and trap as shown in Figure 2.
NOTE:  Hanger Bracket MUST be supported securely.  Add fixture support

carrier if wall will not provide adequate support.

IMPORTANT:

y

6 1/4 in. (159mm) dimension from wall to centerline of trap must be

maintained for proper fit.

y

Anchor hanger securely to wall using all five (5) 1/4 in. dia. mounting

holes.

3) Install straight valve for 3/8" O.D. tube.

INSTALLATION OF COOLER

4) Hang the cooler on the hanger bracket.  Be certain the hanger bracket is

engaged properly in the slots on the cooler back as shown in Figure 2.

5) Loosen the two (2) screws holding the lower front panel at the bottom of

cooler base and two (2) screws at the top (Use torx bits sold separately).
Remove the front panel and set aside.

6) Connect water inlet line--See Note 4 of General Instructions.
7) Remove the slip nut and gasket from the trap and install them on the cooler

waste line making sure that the end of the waste line fits into the trap.
Assemble the slip nut and gasket to the trap and tighten securely.  Recom-
mend fastening cooler to wall using 7/16 bolt holes. (see fig.2, "F")

START UP

Also See General Instructions

8) Stream height is factory set at 45-50 PSI.  If supply pressure varies

greatly from this, adjust screw using the access hole in the pushbutton
(insert screwdriver).  CW adjustment will raise stream and CCW adjust-
ment will lower stream.  For best adjustment, stream should hit basin
approximately 6-1/2” (165mm) from bubbler.

Fig. 3

VANDAL RESISTANT BUBBLER DETAIL

15

1

4

Basin

Содержание VRCTLFR Series

Страница 1: ...do not include all electrical and refrigeration components shown above Other components and rough in are the same as shown INSTALLATION CARE USE MANUAL 20 6 38 39 56 42 1 4 16 7 22 41 See Fig 3 See Fig 6 25 25 45 54 21 43 19 11 32 37 45 45 9 12 13 21 49 33 45 37 16 8 32 33 21 45 23 30 42 16 16 23 30 2 3 5 1 4 51 53 55 50 57 58 58 59 ...

Страница 2: ...ALL B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 2 O D DRAIN STUB 2 IN OUT FROM WALL C 1 1 2 TRAP NOT FURNISHED D ELECTRICAL SUPPLY 3 WIRE RECESSED BOX E INSURE PROPER VENTILATION BY MAINTAINING 6 152 mm MIN CLEARANCE FROM CABINET LOUVERS TO WALL F 7 16 BOLT HOLES FOR FASTENING UNIT TO WALL FIG 2 Page 2 REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDRENS ADA COOLER ADA REQUIREMENT ...

Страница 3: ... dia mounting holes 3 Install straight valve for 3 8 O D tube INSTALLATION OF COOLER 4 Hang the cooler on the hanger bracket Be certain the hanger bracket is engaged properly in the slots on the cooler back as shown in Figure 2 5 Loosen the two 2 screws holding the lower front panel at the bottom of cooler base and two 2 screws at the top Use torx bits sold separately Remove the front panel and se...

Страница 4: ... 2 06 VRCTLFR8 1A Page 4 Fig 4 Refrigerated side shown 30 1 45 8 23 15 25 4 50 RH Unit 55 LH Unit 33 31 24 32 46 45 6 35 36 28 48 44 40 17 18 14 26 47 4 34 52 27 46 46 29 Items 31 24 also used on the LH unit ...

Страница 5: ...ir temperature will drop below 0 F the cooler needs to be drained of all water by blowing out all water lines evaporator item 20 and the drain trap A heater strip is used to heat the unit and will begin to cycle at 40 5 F A check at this temperature will ensure the heater is working and the unit is resis tant to light freezing ALSO MAKE SURE THERE ARE NO PLASTIC OR FLAMMABLE COMPONENTS DIRECTLY AB...

Страница 6: ...penser Side Panel LH Dispenser Side Panel Dispenser Front Panel Front Lower Condenser Shroud Fan Hex Nut Hex Nut Fan Blade Clip Front Rear Panels Strainer See General Instructions Half Nut Regulator Screw 10 x 50 Pinned Torx Screw 8 x 50 Pinned Torx Screw 8 x 62 Torx Slot Washer Heat Exchanger Assy Drain Tailpipe RH unit Cover Cold Control Cover Dispenser Bottom Drain Tube Assy Elbow Assy Drain Ta...

Отзывы: