2000000495 (Rev. A - 01/22)
EDFPBM117WS EDFPBM117WS-F
Page 3
12
TO BUBBLER
12
12
12
14
24
TO BUBBLER
13
TO BOTTLE
FILLER
25
31
Figure 3 - LZWS-EDFPBM117K Tube Routing
REQUIRED TOOLS AND MATERIALS
These tables show special tools and/or additional materials
(not provided) which are necessary to complete installation
of these units:
Figure 2 - EZWS-EDFPBM117K Tube Routing
TO BUBBLER
21
FILTER
ASSEMBLY
13
12
12
WATER
INLET
Special Tools
Item
Description
Quantity
NONE
Additional Materials Not Included
Item
Description
Quantity
Unplated copper inlet pipe
Service Stop/Shut-off Valve
90° 1-1/4” Drain Line
1-1/4” Tee Drain Line
1
2
3
4
1
1
1
1
TO BUBBLER
31
24
TO BOTTLE
FILLER
1.
Make
water supply connections (Fig. 11). Install a shut-off
valve and union connection to building water supply (valve
and union not provided). Turn on water supply and flush
the line thoroughly.
Caution:
DO NOT SOLDER tubes inserted into the
strainer or filter head as damage to the o-rings may result.
2.
Install
mounting frame (instructions supplied with mounting
frame.
3.
(For LZWS-EDFPBM117K) I
nstall the filter head to the bracket,
then install filter bracket on mounting frame (Fig. 10), plumb from
the filter outlet to the chiller inlet with ¼” elbow, poly tubing and
¼ x ¼ union, install filter.
3a.
(For EZWS-EDFPBM117K)
Install strainer on the input tube to
the chiller (Fig. 2).
4.
Install
¼ x ¼ x 3/8 Tee on building water supply tube. Install
supplied 4” poly tubing and armaflex to the outlet of the prev-
ously installed tee. Connect supplied ¼ x ¼ x ¼ tee to the 4” poly
tubing. With the back panel standing close to the frame, connect
3/8” poly tube to the bottle fi
ller.
5.
Hang
main panel on mounting frame hanger. Make sure the
power cord, reset switch wire & poly tube do not get pinched
between the panel & mounting frame. Ensure the panel engages
at the top. Align fountain holes with mounting frame holes.
6.
Remove
protective coating from main panel.
7.
Install
reset switch for bottle filler (Fig. 5). Snap the switch into
position after locating wires through slot. Wrap up the excess
cord.
12