background image

97729C (Rev. C - 1/04)

EDFPA117FPC, EDFPA117FPRAC

PAGE 4

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484

DESCRIPTION

21705C

28322C

21810C

21822C

21823C

21845C

21846C

28227C

28229C

50198C

55001026

70002C

15009C

100322740560

45392C

70410C

70426C

75555C

*75559C

*72000833

75570C

56092C

75520C

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

NS

NS

PART NO.

CLIP-PUSH ROD

BRACKET-PUSH BAR MTG.

PUSH BAR ASSY

FTN BODY&SHELL EDFP110C

FTN BODY&SHELL EDFP114C

COVER PLATE EDFP110C

COVER PLATE EDFP114C

BACK PANEL EDFPA117FRC

BACK PANEL EDFPA117FPRAC

BUSHING-SNAP

BASIN

SCREW-#10 X .50 HHSM

NIPPLE ASSEMBLY

GASKET

BUBBLER

ROD-PIVOT

SCREW #8-32 X .25 THMS

CLIP -.125 STUD LOCK

PUSH ROD ASSY

WASTE ARM ASSEMBLY

SCREW-#10 X .50 PINNED TORX

POLY TUBING (CUT TO LENGTH)

BIT-PINNED TORX T-25

ITEM NO.

PARTS LIST

7, 20

SEE FIG. 5

SEE FIG. 6

4

8

16

15

2

17

9

3

11

1

FIG. 6

FIG. 5

18

* PARTS ARE SUPPLIED WITH FREEZE RESISTANT BOX

12

13

14

10

5

6, 20

19

FIG. 7

INSTALLATION INSTRUCTIONS

   1. Wall should

 already be framed for the fountain using

       the positioning dimensions shown in Figure 3 & 4.

       Shown dimensions pertain to installation location

      (framing must support up to 300 lbs. weight). These

       dimensions are required for compliance with ANSI

       Standard A117.1/ADA requirements.

  

2. Install back panel. 

Place the upper edge of the panel

      above mounting plate on the wall. Slide the panel

      down until it engages the mounting plate. Be sure back

      panel is firmly engaged before releasing it.

  

3. Remove bottom covers

 from fountains and save the

      screws. Assemble push rods to fountains. See Fig. 5.

     (Push rods provided with freeze-resistant boxes).

  

4. Secure the fountains 

to the wall. Install the fountains

      to the back panel using (2) bolts and washers

      (provided) per each fountain. Next secure the fountain

      bodies to the back panel using (4) bolts and washers

      (provided) per each fountain. Tighten securely.

 

 5. Attach drain tubes

 (supplied with freeze-resistant

      box) to fountains and cut to required length using

      freeze resistant box as a guide.

  

6. Install freeze-resistant box 

- see box instructions.

  

7. Install a service stop

 (not provided) and make water

      supply connection from the stop to the strainers in

      the freeze-resistant box.

  

8. Connect fountain water line

 to freeze-resistant

       box - see box instructions. Replace bottom covers.