CARTRIDGE RELACEMENT

Shut off water supplies!
Loosen the screws(2) and raise the
faucet(1). turn the tubes(3) clockwise.

Loosen the cartridge nut (1) and
Remove the old cartridge (2) and
replace with the new cartridge. Replace

the

 

cartridge nut (1) .

CARE AND CLEANING INSTRUCTIONS

Congratulations  on  your  purchase  of  an  Elkay  product.  Although
your product is extremely durable, attention should be given to the
care,  cleaning  and  maintenance  of  this  product.  Cleaning  agents
and  abrasives  may  cause  damage,  which  may  result  in  oxidation
and discoloration.

By following these simple guidelines for proper care and cleaning, it

will give you years of enjoyment:

TO CLEAN: Simply wipe gently with a damp cloth and blot dry with
a soft towel.
A common rule of thumb is:
when you dry off your hands, dry off your product.

·

Avoid  build-up  of  soap,  toothpaste  or  mineral  deposits,  as  these

tend to have an adverse effect on the appearance of the product.

·

NEVER use cleaning products of  any kind on this product -

especially those containing ammonia, bleach or alcohol - or those

with any form of abrasive.

FOR CARE AND MAINTENANCE:

·

The water in certain areas of the world can be very caustic -

standing  water  around  the  product  can  cause  damage.  Be
sure to remove standing water with a dry, soft cloth as soon
as possible.

·

Before applying a protective coating, gently brush the entire

fixture using a soft tooth brush. This will remove any dirt or

    deposit build-up.

·

These simple steps will add temporary protective coating to

your faucet and extend the life of the finish.

Failure to follow care and cleaning will void your warranty.
For additional information, please visit elkayusa.com.

Turn the tubes (3) counterclockwise and
reinstall the faucet(1). 

 

Tighten the

screw (2). Do not overtighten.

Note: Install cartridge

 

correctly for

proper handle rotation.

The faucet ships with a 1.5GPM aerator installed. An
optional 2.2 GPM aerator is also included in the box.
To switch the flow rate of the faucet:

1. Disassemble the quick connect assembly by

separating the connector (1) and quick connect (2).
2. Replace 1.5 GPM connector(green) with the 2.2GPM
connector.
3. Reinstall quick connect assembly.

1

1

2

1

2

FLOW REGULATOR REPLACEMENT

1

2

3

1

2

3

CW to loosen

CCW to tighten

Содержание LKEC2037

Страница 1: ...TOOLS SAVE FOR CONSUMER OPTIONAL 2 2GPM FLOW REGULATOR You choose the flow rate This faucet ships with an eco friendly 1 5GPM flow regulator installed If you desire higher flow rate a 2 2GPM flow regulator has also been included in the box Switching the flow regulator is simple See the Flow Regulator Replacement section for details 1 2 in Supply Lines Important ...

Страница 2: ...ng firmly upward and snap onto receiving block Pull down moderately to ensure connection has been made If it is necessary to remove quick connect squeeze tabs on hose between index finger and thumb then pull down to disconnect After connecting the hose install the weight 4 at the lowest point of the hose Make connections to water lines with 3 8 female compression supply hoses 1 If additional hose ...

Страница 3: ...ining ammonia bleach or alcohol or those with any form of abrasive FOR CARE AND MAINTENANCE The water in certain areas of the world can be very caustic standing water around the product can cause damage Be sure to remove standing water with a dry soft cloth as soon as possible Before applying a protective coating gently brush the entire fixture using a soft tooth brush This will remove any dirt or...

Страница 4: ... defect and model number or description of model and or component part THIS LIMITED WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES EXPRESSED IMPLIED ARISING BY LAW OR OTHERWISE INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THIS LIMITED WARRANTY MAY NOT BE ALTERED VARIED OR EXTENDED EXCEPT BY A WRITTEN INSTRUMENT EXECUTED BY ELKAY TH...

Отзывы: