FD700_3_2JJO, FD700_5_2JJO

1000003126 (Rev. A - 12/15)

Installation

For correct and safe installation, please read these instructions completely.

     •     All Installation work must be performed by an authorized service personnel.

     •     Disconnect electrical supply serving the Installation area to reduce risk of electrocution.

     •     Unit not suitable for installations where water jets could be used. 

DANGER

WARNING

     •     Shut off water supply serving the Installation area to reduce risk of water damage.

     •     Ensure proper ventilation by maintaining clearance from cabinet louvers to wall on each side of Cooler as specified in Rough-In.

     •     Never wire compressor directly to electrical supply.

     •     Do not solder tubes inserted into the In-line Strainer as damage to the o-rings may result.

     •     Thoroughly flush all water lines and fittings of all foreign matter before connecting to Cooler.

     •     Warranty is void if the plumbing kit or glass filler is not specified for use by the Manufacturer for this particular model.

     •     Warranty is void if Installation is not made in accordance with current Manufacturing instructions.

CAUTION

     •     Hose-sets are not to be used for connecting to water mains.

     •     If inlet pressure is above 100 psig (0.69 MPa), a pressure regulator must be installed in water supply line. Any damage caused by

           reason of connecting this product to water supply line pressure outside its rated pressure, is not covered by warranty.

     •     This cooler is manufactured in such a manner that it does not in any way cause taste, odor, color, or sediment problems. If a taste,

           odor or sediment problem is prevalent, try installing our water filter on the supply line.

     •     Tools/Items required but not provided.

                   o       Water Shut-off Valve with 3/8” (9.5mm) compression outlet.

                   o       1-1/4" (31.8mm) Waste Trap (non-metallic)

                   o       Safety Glasses

                   o       Protective Gloves

                   o       5/16" (7.9mm) Hex Driver or Flathead Screwdriver

                   o       C-13 Modular International Power Cord Set

Installation: Cooler Mounting

1. 

Select installation location. Installation location must be a flat surface.  Installation location should ensure proper ventilation by maintaining 4" 

(102mm) minimum clearance from cabinet louvers to wall.

2.  Remove front panel (Item 26) by unscrewing (2) 5/16" (7.9mm) Hex Head screws.  Set panel aside. 

3.  Installation area must also include water supply, electrical supply and suitable drain. Water, drain and electrical supply systems must comply 

with local code requirements.

     

Installation: Water Line connection

1.  Ensure Mains Water Supply has Water Shut-off Valve with 3/8” (9.5mm) compression outlet.

2.  Connect loose end of supplied 3/8” (9.5mm) unplated copper tube to Water Shut-off Valve.  See Figure 1.

• 

NOTE: If 3/8” (9.5mm) copper tube must be cut for proper fit, remove all burrs from the outside of tube and re-flush before use.

3.  Install waste trap. Remove the slip nut and gasket from the waste trap and install them on the Cooler waste line making sure that the end of the 

waste line fits into the waste trap. Assemble the slip nut and gasket to the trap and tighten securely.

4.  Turn on building water supply and open Water Shut-off Valve. Check all connections for leaks and correct any found.

Installation: Electrical connection

1.  Rotate fan to insure proper clearance and free fan action.

2.  Connect modular (C-13) end of International Power Cord Set (sold separately) into Power Inlet on unit and ensure plug-end reaches electrical 

outlet. Do not plug into electrical outlet!

NOTE: WATER FLOW

DIRECTION

BUILDING WATER SUPPLY

WATER SHUT-OFF VALVE

(NOT PROVIDED)

1/4" O.D. TUBE

WATER INLET

3/8" (9.5mm) O.D. 

UNPLATED COPPER TUBE

IN-LINE 

STRAINER 

(PROVIDED)

Figure 1

Figure 2

A = White (Neutral)

B = Black (230Vac)

C = Ground (Earth)
D = Fan

E = Freeze Control (when provided)

F = Cold Control (Water)

G = Hot Tank Switch (When Provided)

H = Hot Tank (when provided)

I = Capacitor (when provided)

POWER INLET

Содержание FD7003*F2YJO Series

Страница 1: ...ion keep these instructions in a safe location for future reference Electric supply must be identical in voltage cycle and phase to that specified on nameplate Electrical supply must have Ground Fault Circuit Interrupter GFCI protection A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules This is to allow electrical discon...

Страница 2: ... Gloves o 5 16 7 9mm Hex Driver or Flathead Screwdriver o C 13 Modular International Power Cord Set Installation Cooler Mounting 1 Select installation location Installation location must be a flat surface Installation location should ensure proper ventilation by maintaining 4 102mm minimum clearance from cabinet louvers to wall 2 Remove front panel Item 26 by unscrewing 2 5 16 7 9mm Hex Head screw...

Страница 3: ...Service For proper and safe servicing please read these instructions completely All Service and Maintenance must be performed by an authorized service personnel Disconnect electrical supply to the unit before any service work to reduce risk of electrocution Shut off water supply serving the unit before any service work to reduce risk of water damage DANGER CAUTION Tools Items required but not prov...

Страница 4: ...r and clean if required See Figure 6 6 Lubrication Motors are lifetime lubricated 7 Actuation of Quick Connect Water Fittings Cooler is provided with lead free connectors which utilize o ring water seal To remove tubing from the fitting relieve water pressure push in on the gray collar before pulling on the tubing To insert tubing push tube straight into fitting until it reaches a positive stop ap...

Страница 5: ...73C 36243C 98748C 66704C 0000000241 0000000254 66809C 98773C 35827C 0000000243 30824C 56237C 42677000 21958C 21482C 20460C 21959C 21487C 21486C 21239C 28196C 66743C 35826C 31486C 31455C 31456C 31457C 31458C 31459C 31460C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 NS NS Kit Push Button Assy Kit Regulator w Spring Gasket GF Bubbler Nipple Assy GF Strainer Tubing Poly Cut to Lengt...

Отзывы: