Page 7

EZWSMD*1A     EZWSM8*1A     EZWSM8*2A     LZWSMD*1A     LZWSM8*1A     LZWSM8*2A

98557C (Rev. R - 11/20)

VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the 

    unit will need to be shut down and restarted. The chiller

    (if present) does not need to be shut down and restarted.

2) The units lower panel must be open to access the power 

    cord and wall outlet.

3) Shut down the unit by unplugging the power cord from the 

    wall outlet. 

4)  Restart the unit by plugging the power cord back into the 

    wall outlet.

5) Upon start up the bottle count display will show the 

    software designation of BF6, BF7, BF8, BF9 or BF11. 

6) Reference the BF6-BF7-BF8-BF9 or BF11 instructions for

    setting the control board.

ACCESSING THE PROGRAMMING BUTTON

1)   To access the program button the lower panel of the

      unit must be must be opened. The programming button is 

      located at the bottom right corner of the upper panel.

     This area of the unit is concealed by the lower panel.

RESET THE FILTER MONITOR

1) Instructions apply to filtered units only.

2) Depress the program button for approximately 2 seconds

    until the display changes then release. The display will

    change and scroll through two messages:

       “RST FLTR” – Reset Filter Monitor

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display

    will scroll through the two messages above for

    three cycles and then default back to bottle count and

     be back in run mode.

3) When the display changes to “RST FLTR”, depress

    the button again. The display will change to show

     “FLTR =”. Depress the button again and the display

    will show “FLTR =0”

4) The Green LED should be illuminated indicating that

    the visual filter monitor has been reset. 

 SETTING RANGE OF THE IR SENSOR

1) Depress the program button for approximately 2 seconds

    until the display changes then release. The display will

    change and scroll through two messages:

       “RST FLTR” – Reset Filter Status LED

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display 

    will scroll through the two messages above for 

    three cycles and then default back to bottle count 

     and be back in run mode.

2) When the display changes to “SETTINGS”, depress

    the button again. The display will change to show

     “RNG SET“-  Range set for IR sensor.

      “UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)

     “RST BCNT“ - Reset bottle count

3)  When display shows “RNG SET” push program

    button once the display will show current value

     (can be 1 – 10) e.g. “RNG = 3”.

4) Once display shows current value push the 

    program button to scroll through value of 1 – 10.

    Select the desired range setting.

5) Once range is selected allow approximately

    4 seconds to pass and then the display will go 

     back to bottle counter and be in run mode.

6)  Test bottle filler by placing bottle or hand in front

    of sensor to make sure water is dispensed.

SETTING UNIT TYPE

1) Depress the program button for approximately 2 seconds

    until the display changes then release. The display will

    change and scroll through two messages:

      “RST FLTR” – Reset Filter Status LED

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display 

    will scroll through the two messages above for 

    three cycles and then default back to bottle count 

      and be back in run mode.

2)  When the display changes to “SETTINGS”, depress

    the button again. The display will change to show

     “RNG SET“-  Range set for IR sensor.

       “UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)

      “RST BCNT“ - Reset bottle count

3)  When display shows “UNIT TYPE” push program 

    button once the display will show current value

       Can be REFRIG or NON-RFRG

4) Push button once to change value. Once value is

      selected the display will show the new value.

       (Can be REFRIG or NON-RFRG)  

     “REFRIG“ - stands for refrigerated product. In this 

     setting the flow rate is estimated at 1.0 gallon per minute.

     “NON-RFRG“ - stands for nonrefrigerated product. 

    In this setting the  flow rate is estimated 

      

at 1.5 gallons per minute.

      Both “REFRIG“ and “NON-RFRG“ simulate 

       1 bottle equal to 20 oz.

5) 

 Allow approximately 4 seconds to pass and the display

     will return to bottle counter and be in run mode.

    

 RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds

    until the display changes then release. The display will

    change and scroll through two messages:

      “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display 

    will scroll through the two messages above for 

    three cycles and then default back to bottle count 

     and be back in run mode.

2)  When the display changes to “SETTINGS”, depress

    the button again. The display will change to show

     “RNG SET“-  Range set for IR sensor.

       “UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)

      “RST BCNT“ - Reset bottle count

    If the button is not pushed again the display will scroll

    through the three messages above for the cycles and

     return to run mode.

3)  When display shows “RST BCNT” push program button

    once the display will show current value e.g. “00033183”.

4) Once display shows current value push the program

    button once more to reset back to 0. The display will

    show BTLCT = 0 for approximately 2 seconds and 

    then return to run mode showing 00000000 bottles.

5) 

 Testing the bottle counter:

     REFRIG units: Place bottle or hand in front of sensor

       for 9.4 seconds to see bottle counter count 00000001.

     

    (This is based on filling a 20 oz. bottle)

     NON-RFRG units: Place bottle or hand in front of sensor

       for 6.25 seconds to see bottle counter count 00000001.

         (This is based on filling a 20 oz bottle)

BF9 PROGRAM

SETTING THE CONTROL BOARD

WWW.RESTROOMDIRECT.COM      704•937•2673     129 Oakpark Dr., Unit A, Mooresville, NC 28115

Содержание ezH2O EZWSM8 Series

Страница 1: ...ASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO E...

Страница 2: ...OTHERS BACK WALL LINE 8 203MM MINIMUM FOR DRAIN CONNECTION AND ACCESS TO BOTTLE FILLER ELECTRICALS FINISHED FLOOR 25 1 4 642mm 27 682mm 2 7 8 73mm 25 7 8 657mm 1 1 4 32MM WASTE TUBE FURNISHED 3 1 2 89...

Страница 3: ...657mm 1 1 4 32MM WASTE TUBE FURNISHED 3 1 2 89mm 4 1 2 117mm 1 1 8 29mm 11 279mm ELECTRICAL INLET FINISHED FLOOR 17 3 8 441mm 1 3 16 30mm 1 3 16 30mm 19 3 4 502mm 21 15 16 557mm 38 7 8 988mm 18 7 8 48...

Страница 4: ...LLATION Fig 6 Filter units only For non filtered units proceed to step 15 NOTICE Do not use water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after t...

Страница 5: ...minimum space of 4 102mm on top sides and a depth of 12 305mm 20 Remove Chiller Front panel Remove the 10 screws securing chiller front panel 21 Connect electrical to chiller Make sure power supply i...

Страница 6: ...icating that the visual filter monitor has been reset SETTING RANGE OF THE IR SENSOR 1 Depress the program button for approximately 2 seconds until the display changes then release The display will ch...

Страница 7: ...be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed SETTING UNIT TYPE 1 Depress the program button for approximately 2 seconds until the d...

Страница 8: ...o show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 When display shows UNIT TYPE push program button once the...

Страница 9: ...S 1 800 260 6640 DESCRIPTION 98543C 98544C 98545C 98546C 98549C 98631C 98632C Kit Electrical Package Kit EE Sensor Kit Solenoid Valve Replacement Kit Aerator Replacement Kit Hardware Waterway Parts Ki...

Отзывы: