EMASMB*A & LMASMB*A
Instruction for Use
1.
Place container under the dispenser nozzle
and depress the actuator button. Hold until container is filled to the level desired.
2.
To stop water flow,
release actuator button. Pull container away from dispenser nozzle.
Connect Plumbing Lines. NOTE: Connecting to water mains must be in compliance with local and national laws.
1.
Connect water supply line to unit:
NOTE: Hose-sets are not to be used for connecting to water mains.
2.
Connect the 3/8"O.D. Copper tube
from the in-line strainer to the 3/8" to the Service Stop Valve.
3.
Connect the 1-1/4"O.D. Drain Tray Outlet
to the in-wall Drain Line using a Slip Joint Drain Union or compression clamp
(not supplied). Tighten all connections water tight.
4.
Turn water supply on,
inspect for leaks and correct any leaks before continuing.
Wall Mounting (
reference Rough-Ins, Fig. 1 and Fig. 2
)
1.
Remove Top Cover from Bottle Filler
by removing two (2) screws from bottom of unit. Use a 5/32" hex wrench (not supplied).
2.
Remove Bottom Cover from Bottle Filler
by removing two (2) screws from bottom of unit. Use a 5/32" hex wrench (not
supplied).
3.
With the Top and Bottom Covers removed,
the Back panel is now free to be removed from Bottle Filler.
4.
Fasten Back Panel to structurally secure wall
thru five 7/16" obround holes with fasteners appropriate for wall type. Locate
Back Panel as specified in Rough-In. If necessary, attach to Wall Support Carrier (not supplied).
5.
Ensure Back Panel is not obstructed
by the roughed-in Water and Drain Lines. If Back Panel is prevented from seating
properly, reposition Water and/or Drain Lines slightly until the Bottom Cover fits easily.
6.
Before hanging the On-Wall Bottle Filler,
ensure the Insulated Waterline is routed inside of the Wrapper. If outside the
Wrapper, reposition to inside or else the unit cannot be installed properly.
7.
Hang the Bottle Filler onto the Back Panel,
aligning two tabs onto the top of the Back Panel.
8.
Secure Bottle Filler to Back Panel
by replacing Top Cover on top of unit and fastening with two (2) supplied screws.
9.
Replace the Bottom Cover
on bottom of the unit and fasten in place with two (2) supplied screws.
Changing the Filter
1.
Remove the Bottom Cover
of the Bottle Filler by removing the two (2) screws.
2.
Remove (1) screw
and loosen other on filter tray and slide out to allow access to the filter.
3.
Release filter from water lines
(see Figure 3, Page 6) for operation of quick connect fittings.
4.
Remove new filter from carton,
remove protective cap; cap may be placed on an old filter to reduce the chance of the water
spilling from filter housing.
5.
Attach filter to water lines
(see Figure 3, Page 6) for operation of quick connect fittings.
6.
Actuate Bottle Filler
until approximately 1 gallon of water is dispensed. This flushing procedure purges air and fine carbon
particles from the filter.
Installing/Replacing Batteries:
1.
Remove Bottom Cover from Bottle Filler
by removing two (2) screws from bottom of unit. Use a 5/32" hex wrench (not
supplied. The battery tray is located on the bottom cover. Install the (3) "AA" batteries in the battery tray.
2.
Confirm unit is on:
Display will show
00000000
2.1.
Filtered Units:
The Filter Status Green LED will be illuminated momentarily to show filter status when button is pushed and
the Bottle Counter LCD on the Nameplate displays bottle count.
2.2.
Non-Filtered Units:
The Bottle Counter LCD on the Nameplate displays bottle count.
3.
Ensure water dispenses:
Activate unit by depressing the button. Water should flow. It is normal for the water stream to sputter
with air when the unit is new or a new filter cartridge is installed.
4.
Ensure a steady water flow is obtained:
Activate unit per above and hold until all air entrapped in lines and filter is purged.
Multiple activations may be required.
5.
Inspect for leaks
and if any found, correct before continuing.
6.
If setting up the Control Board
for the first time, go to
Setting the Control Board section before continuing.
7.
Place Bottom Cover in position
on underside of unit with long tab against wall and slide up into Back Panel opening. Secure
with two supplied Allen head screws using a 5/32" hex-wrench (not supplied).
Plumbing Connections
• Ensure lines and ports remain clean and free of contaminants during assembly.
• Purge each component if necessary.
• To ensure quick-connect connections seal properly, follow instructions per Figure 3, Page 6.
INSTALLATION INSTRUCTIONS