97062C (Rev. A - 3/98)
EIOA4/8*1B, EIOA4/8*2B
PAGE 3
SENSOR RANGE ADJUSTMENT
: The electronic sensor used in this cooler is factory pre-set for a "visual" range of 36
inches (914 mm). If actual range varies greatly from this or a different setting is desired, follow the range adjustment
procedure below:
A. Remove front panel of cooler.
B. Using a small tip screwdriver, rotate range adjustment screw clockwise to increase range and counterclockwise to
decrease range (See Fig. 3).
CAUTION
: Complete range of sensor (24-28 inches/610-711mm) is only one turn of the adjusting screw.
C. Replace front panel.
SENSOR CONTROL
: If sensor fails to operate valve mechanism or operates erratically, check the following.
A. Ensure there are no obstructions within a 40 inch (1016mm) radius in front of cooler.
B. Check wire connections at the solenoid valve and sensor.
CAUTION
: Make sure unit is unplugged before checking any
wiring.
C. Ensure proper operation of solenoid valve. If there is an audible clicking sound yet no water flows, look for an obstruction
in the valve itself or elsewhere in the water supply line.
17
14
13
NOTE: WATER FLOW DIRECTON
RANGE
ADJUSTMENT
SCREW
7
14
10
6
14
FIG. 3
HANGER BRACKETS & TRAP
INSTALLATION
1
) Remove hanger bracket fastened to back of cooler by re-
moving one (1) screw.
2) Mount the hanger bracket and trap as shown in Figure 2.
NOTE:
Hanger Bracket MUST be supported securely. Add
fixture support carrier if wall will not provide adequate sup-
port.
IMPORTANT:
7-3/4 in. (197mm) dimension from wall to centerline of
trap must be maintained for proper fit.
Anchor hanger securely to wall using all six (6) 1/4 in. dia.
mounting holes.
3) Install straight valve for 3/8" O.D. tube.
INSTALLATION OF COOLER
4) Hang the cooler on the hanger bracket. Be certain the
hanger bracket is engaged properly in the slots on the
cooler back as shown in Figure 2.
5) Loosen the two (2) screws holding the lower front panel at
the bottom of cooler base and two (2) screws at the top.
Remove the front panel and set aside.
6) Connect water inlet line--See Note 4 of General Instruc-
tions.
7) Remove the slip nut and gasket from the trap and install
them on the cooler waste line making sure that the end of
the waste line fits into the trap. Assemble the slip nut and
gasket to the trap and tighten securely.
START UP
Also See General Instructions
8) Stream height is factory set at 35 PSI. If supply
pressure varies greatly from this, adjust screw, ac-
cessible by removing front panel (Item 7, Fig. 3).
CW adjustment will raise stream and CCW adjust-
ment will lower stream. For best adjustment, stream
should hit basin approximately 6-1/2 (165mm) from
bubbler.
9) Replace the front panel and secure by retightening
four (4) screws.
ITEM NO.
PART NO.
Panel-Bottom Dispenser
Bracket-Valve Mounting
Sensor-Clear (115V)
Sensor-Clear (230V)
Solenoid Valve (115V)
Solenoid Valve (230V)
Panel-Right Side
Panel-Left Side
Panel-Front
Elbow 1/4 Stem x 1/4 O.D.
Fitting 1/4 NPTF x 1/4 O.D.
Nut-Cover Unplated
Screw-#6-32 x 1/2" Lg. PHMS
Screw-#10 x 1/2" Lg. THSM
Clip
Screw-#8 x 5/8" Lg. Torx/Slot
Hex Nut
Retaining Nut
Regulator
Holder-Regulator
Screw-#10 x 1/2" Lg. HHSM
22897C
26729C
31516C
35783C
31272C
35784C
See Color Table
See Color Table
See Color Table
70817C
75507C
40116C
70644C
75532C
70254C
70864C
40045C
15005C
61314C
50986C
70002C
Item No. 5
Part No.
COLOR TABLE
Bronzetone
Gray Beige
Almond
Stainless Stl
Sandalwood
Granite
27502C
23015C
23016C
22822C
23017C
23020C
27432C
23008C
23009C
22814C
23010C
23013C
27591C
23161C
23162C
23137C
23164C
27217C
PANEL
COLOR
Item No. 6
Part No.
Item No. 7
Part No.
11
2
15
11
3
57
4
12
14
5
16
18
8
9
19
9
1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DESCRIPTION