98294C (Rev. D - 5/10)
EFHA8*1K EFHA8*2KJO
PAGE 2
18" 457
m
m
23
"
5
84m
m
2 1/
2"
64
m
m
5" 1
27m
m
40
"
10
1
6
m
m
41 1/
2
"
105
4m
m
4
5/
8"
118
m
m
14
1/
2"
36
8m
m
C
A
B
D
E
E
G
F
FIG
. 2
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
E = INSURE PROPER VENTILA
TION BY
MAINT
AINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO
W
ALL.
ASEGURE UNA
VENTILACIÓN
ADECUADA
MANTENIENDO UN ESP
ACIO E 4" (102mm) (MÍN.) DE HOLGURA
ENTRE LA
REJILLA
DE VENTILACIÓN DEL
MUEBLE
Y
LA
P
ARED
ASSUREZ-VOUS UNE BONNE VENTILA
TION EN GARDANT
4" (102mm) (MIN.) ENTRE LES ÉVENTS DE L
’ENCEINTE ET
LE
MUR.
F = POWER CORD 4 FEET (1219mm) LONG
CABLE ELÉCTRICO DE 4 PIE (1219mm), DE LARGO
CORDON D’ALIMENT
A
TION 4' (1219mm)
G = PLUMBING ROUGH-IN CAN BE LOCA
TED
ANYWHERE WITHIN THIS
A
R
E
A
.
SE PUEDE COLOCAR EL
DESBASTE DE LA
TUBERÍA
EN CUALQUIER LUGAR DENTRO DE EST
A
ÁREA.
ON PEUT
PLACER LA
T
U
Y
AUTERIE DANS CETTE RÉGION.
LEGEND/LEYENDA/LÉGENDE
A
= RECOMMENDED W
A
TER SUPPL
Y
LOCA
TION 3/8 O.D. UNPLA
TED COPPER TUBE CONNECT STUB 1-1/2 IN. (38mm)
OUT
FROM WALL SHUT OFF BY OTHERS
SE RECOMIENDA
UBICAR EL
TUBO COR
T
O
DE CONEXIÓN
AL
TUBO DE COBRE SIN CHAP
AR DE 3/8" DE DIÁM. EXT
. A
1-1/2"
(38mm) FUERA
DE LA
LLA
VE DE P
ASO EN LA
P
ARED COLOCADA
POR
TERCEROS.
EMPLACEMENT
RECOMMANDÉ D'ALIMENT
A
TION EN EAU P
AR
TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 mm) D.E.
CONNECT
ANT
UNE
T
U
Y
AUTERIE DE 1-1/2 PO. (38mm) DEPUIS LE ROBINET
D'ARRÊT
FOURNI P
AR D'AUTRES.
B = RECOMMENDED LOCA
TION FOR W
ASTE OUTLET 1-1/4” O.D. DRAIN
UBICACIÓN RECOMENDADA
P
ARA
EL
DRENAJE DE SALIDA
DE
AGUA, DE 1¼” DE DIÁMETRO.
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE D’EAU.
C = 1-1/4 TRAP NOT FURNISHED**
PURGADOR DE 1¼ NO PROPORCIONADO**
SIPHON 1-1/4 NON FOURNI**
D = ELECTRICAL
OUTLET LOCA
TION
UBICACIÓN DE LA TOMA DE ELECTRICIDAD
EMPLACEMENT DE LA PRISE DE COURANT