Page 10

Elkay Manufacturing Company 

  

(630) 574-8484 

 

 

2000000696 (Rev. A - 07/22)

ECH8GRN_1C           

WHT

GND

BLK

FAN

3

1

2

5

M

S

C

1

2

3

COLD

CONTROL

(WATER)

6

RELAY

OVERLOAD

COMPRESSOR

RUN

CAPACITOR

Wiring Diagram

TUBE IS SECURED

IN POSITION

SIMPLY PUSH IN

TUBE TO ATTACH

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

Operation of Quick Connect Fittings

Fig. 2

NOTE: WATER FLOW

DIRECTION

BUILDING WATER INLET

SERVICE STOP

(NOT FURNISHED)

1/4" O.D. TUBE

WATER INLET

TO CHILLER

3/8" O.D. UNPLATED COP-

PER TUBE CONNECT

COLD WATER SUPPLY

Fig. 1

Fig. 3

Содержание ECH8GRN

Страница 1: ...ECH8GRN_1C 630 574 8484 Elkay Manufacturing Company 2000000696 Rev A 07 22 Page 1 ECH8GRN Refrigeration Package INSTALLATION CARE AND USE MANUAL...

Страница 2: ...nstallation Preparation Read Before Beginning Installation 7 4 Tools and Supplies 7 4 1 Tools Required 7 4 2 Installer Supplied Parts 7 4 3 Tools Items required but not provided 7 5 Ratings 7 5 1 ECH8...

Страница 3: ...Symbol and followed by a signal word such as WARNING or CAUTION 1 3 Definitions DANGER The signal word that indicates a hazard with a high level of risk which if not avoided will result in death or s...

Страница 4: ...any maintenance make sure the unit is unplugged and circuit breakers are turned OFF Prior to installation test for live circuits or wiring inside the wall before cutting or drilling into the wall Fai...

Страница 5: ...e installed properly by trained service person 2 2 Disclaimer The information contained in this Installation Use Care Manual is given free of charge It is based upon technical data which we believe to...

Страница 6: ...4 261mm 17 3 8 441mm 1 3 4 95mm REF C D 1 3 8 35mm 2 50mm A B 13 1 4 338mm 1 25mm 3 3 4 57mm LEGEND A 1 4 O D TUBE WATER OUTLET B 1 4 O D TUBE WATER INLET C TEMPERATURE ADJUSTMENT D ELECTRICAL USES HF...

Страница 7: ...uce risk of water damage Thoroughly flush all water lines and fittings of all foreign matter before connecting to chiller If inlet pressure is above 100 psig 0 69 MPa a pressure regulator must be inst...

Страница 8: ...louvers on each side of chiller When mounting unit in a cavity or behind a wall maintain a minimum space of 4 102mm on each side 4 102mm on the top and a depth of 12 305mm 6 Water inlet is 1 4 6 mm O...

Страница 9: ...ces 9 2 1 Condenser Fan Motor Visually check and confirm the condenser fan turns freely If the condenser fan does not spin freely have an authorized service personnel to check and replace the fan 9 2...

Страница 10: ...ring Diagram TUBE IS SECURED IN POSITION SIMPLY PUSH IN TUBE TO ATTACH PUSH IN COLLET TO RELEASE TUBE PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE Operation of Quick Connect Fittings Fi...

Страница 11: ...ll correspondence pertaining to any of the above wa ter chiller or orders for repair parts MUST include model number and serial number of chiller name and part number of replacement part Evaporator Re...