97910C (Rev. A - 10/02)

EWHA8, 14*1F, 2F

PAGE 2

FIG

. 2

INSURE 

PROPER 

VENTILA

TION BY 

MAINT

AINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS T

O

 W

ALL.

ASEGURE UNA

 VENTILACIÓN 

ADECUADA

 MANTENIENDO UN ESP

ACIO E 4" (102mm) (MÍN.) DE HOLGURA

 ENTRE LA

REJILLA

 DE VENTILACIÓN DEL

 MUEBLE Y

 L

PARED

ASSUREZ-VOUS UNE BONNE VENTILA

TION EN GARDANT

 4

" (102mm) (MIN.) ENTRE LES ÉVENTS DE L

’ENCEINTE 

ET

 L

E

MUR.

F = POWER CORD 4 FEET (1219mm) LONG

CABLE ELÉCTRICO DE 4 PIE (1219mm), DE LARGO CORDON D’ALIMENT

ATION 4' (1219mm)

G = PLUMBING ROUGH-IN CAN BE LOCA

TED 

ANYWHERE WITHIN THIS 

AREA.

SE 

PUEDE 

COLOCAR 

EL

 DESBASTE 

DE 

LA

 TUBERÍA

 EN CUALQUIER LUGAR DENTRO DE EST

ÁREA.

ON PEUT

 PLACER LA

 T

U

YAUTERIE DANS CETTE RÉGION.

40" (1016mm) RECOMMENDED HEIGHT FOR 

ADUL

TS

A

LTURA

 RECOMENDADA

 P

ARALOS

ADUL

TOS 40" (1016 mm)

HAUTEUR RECOMMANDÉE POUR LE

S

 ADUL

TES 40" (1016mm)

33" (838mm) RECOMMENDED HEIGHT FOR CHILDREN

A

LTURA

 RECOMENDADA

 P

A

R

LOS

NIÑOS 33" (838 mm) HAUTEUR RECOMMANDÉE POUR LES ENFANTS 33" (838mm)

FINISHED FLOOR

PISO ACABADO PLANCHER FINI

LEGEND/LEYENDA/LÉGENDE A

 = RECOMMENDED W

ATER 

SUPPL

Y

 LOCA

TION 3/8 O.D. UNPLA

TED COPPER TUBE CONNECT STUB OUT 1-1/2 IN. (38mm)

FROM WALL SHUT OFF BY OTHERS

 SE RECOMIENDA

 UBICAR EL

 TUBO 

CORT

O

 DE CONEXIÓN 

A

TUBO DE COBRE SIN CHAP

AR DE 3/8" DE DIÁM. EXT

. A

 1-1/2"

(38 

m

m

) FUERA

 D

E

 L

A LLA

V

E

 D

E

 P

ASO EN LA

 P

ARED 

COLOCADA

 POR 

TERCEROS.

        EMPLACEMENT 

RECOMMANDÉ 

D'ALIMENT

ATION 

EN 

EAU 

PA

R

 TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 m

m

) D.E.

CONNECT

A

N

UNE 

TU

YAUTERIE DE 1-1/2 PO. (38 m

m

) DEPUIS LE ROBINET

 D'ARR

Ê

T FOURNI P

AR D'AUTRES.

B = RECOMMENDED LOCA

TION 

FOR 

W

ASTE OUTLET 1-1/4” O.D.  DRAIN

 UBICACIÓN RECOMENDADA

 P

A

R

E

DRENAJE 

DE 

SALIDA

 D

E

 AGUA, DE 1¼” DE DIÁMETRO.

EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE D’EAU.

C = 1-1/4 TRAP NOT FURNISHED

PURGADOR DE 1¼ NO PROPORCIONADO SIPHON 1-1/4 NON FOURNI

D = ELECTRICAL OUTLET LOCA

TION

UBICACIÓN DE LA TOMA DE ELECTRICIDAD EMPLACEMENT DE LA PRISE DE COURANT

Содержание 141F Series

Страница 1: ... 14 1F 2F PAGE 1 With FLEXI GUARD Installation Care Use Manual USES HFC 134A REFRIGERANT FIG 1 34 SEE FIG 5 SEE FIG 3 7 29 31 32 14 8 SEE FIG 4 43 26 22 23 24 25 45 46 17 18 19 20 44 13 33 SEE PAGE 3 30 15 16 21 27 41 42 47 28 ...

Страница 2: ...GHT FOR CHILDREN ALTURA RECOMENDADA PARA LOS NIÑOS 33 838 mm HAUTEUR RECOMMANDÉE POUR LES ENFANTS 33 838mm FINISHED FLOOR PISO ACABADO PLANCHER FINI LEGEND LEYENDA LÉGENDE A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB OUT 1 1 2 IN 38mm FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3 8 DE DIÁM EXT A 1 1 2 3...

Страница 3: ... HOLD PARTS SNUG IN POSITION DO NOT OVER TIGHTEN FIG 4 BASIN 9 10 11 12 8 4 3 1 5 6 2 WIRING DIAGRAM This Drawing is merely for illustrating the components of the electrical system A54731 A54732 70793C A54729 30511C 50226C 28365C 70606C 70302C 70836C 28366C 28367C 1 2 3 4 5 6 7 8 9 10 NS PART NO DESCRIPTION ITEM NO HOT TANK PARTS LIST Hot Tank Weldment Assy 115V Hot Tank Weldment Assy 220V 1 4 Elb...

Страница 4: ...14 GPH Gasket Drain Flow Regulator Assy 40089C 40048C 15005C 61313C 40169C 50986C 21541C 56073C 40322C 56011C 55997C 75580C 31513C 36132C 66417C 66432C 21516C 36144C 31491C 30664C 27681C 70018C 66202C 66203C 35762C 35775C 31027C 35840C 31797C 35768C 194243901550 55996C 45448C 56092C 66229C 66445C 66505C 66506C 21591C 30010C 36154C 45786C 40597C 92712C 51543C 40596C 70921C 33659000 50368C 70750C 70...

Отзывы: