background image

754747-100

1

THANK  YOU...

for selecting an Eljer bathing product. Your new bath is shipped to you after careful inspection. The whirlpool is 
completely assembled with pump and circulatory system piping. All you need to finish the installation are your 
selected fittings and electrical connections.

To ensure maximum performance and pleasure from this product, please follow the instructions and cautions. 

© Eljer 2011
All product names listed herein are trademarks of Eljer unless otherwise noted.

For questions or service issues, please call Technical Support 1-(800)-442-1902.
Please do not contact or return product to the store.

MODEL NUMBERS

2932J048 & 2940J048

           STRATUS   

WHIRLPOOL

INSTALLATION AND 

OPERATION MANUAL

TM

Содержание 2932J048

Страница 1: ...cted fittings and electrical connections To ensure maximum performance and pleasure from this product please follow the instructions and cautions Eljer 2011 All product names listed herein are trademarks of Eljer unless otherwise noted For questions or service issues please call Technical Support 1 800 442 1902 Please do not contact or return product to the store MODEL NUMBERS 2932J048 2940J048 ST...

Страница 2: ...e 3 Installation Framing and Post Installation Clean Up Instructions Page 4 Roughing in References for All Model Series Pages 5 6 General Specifications for Whirlpools Page 7 8 Electrical Installation Instructions Page 9 Operating Instructions Page 10 Cleaning and Maintenance Page 11 Warranty Page 12 ...

Страница 3: ...ss of consciousness or even drowning WARNING Pregnancy If you are or think you may be pregnant consult your physician before using the bathtub Never drop or insert any object into any opening Use this unit only for its intended use as described in this manual Do not use any attachments not recommended by American Standard The unit must be connected only to a supply circuit that is properly protect...

Страница 4: ...so the rim of the bath contacts the stringer or pier but supports no weight Provisions must be made in all installations for an access opening for servicing the bath pump Unless an access opening of at least 12 x 24 305mm x 610mm is provided warranty service will not be performed It is strongly recommended that an additional opening be provided for access to drain components Each bath has a nomina...

Страница 5: ...ed separately TYPICAL TILE BEAD INSTALLATION 24 610 mm 12 305 mm C E D W LEVELING STRINGERS ACCESS PANEL MUST BE LOCATED ON THE SAME SIDE AS THE MOTOR ALLOW OPEN FRAMING ON PUMP MOTOR END FOR SERVICE UNLESS AN ACCESS OPENING OF AT LEAST 12 x 24 305 x 610mm IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED NOTE FRONT EDGE OF BATH MUST BE SUPPORTED BY STUD WALL OR ELJER APRON KIT ACCESS PANELS NOT ...

Страница 6: ...e outer edge of the traced line 6 Replace the bath deck and secure it into place 7 Apply additional sealant along the tub and bath deck interface as necessary to ensure a watertight seal 8 Remove excess sealant per the manufacturer s instructions Finished bath deck surface material must be self supporting and secured per local codes Tub support structure per installation instructions provided with...

Страница 7: ... Loading Product Weight 54 gal 205 l Whirlpool Operation Volume Gallons to Overflow Height to Underside of Deck C Dimensions L W H A 17 3 4 451mm B 10 7 8 276mm C 20 1 2 521mm 58 1 4 1480mm x 30 1 4 768mm 59 15 16 1522mm x 30 1 4 768mm L 59 3 4 1518mm W 31 3 4 806mm H 22 1 2 572mm 2932J048 5 x 32 Stratus TABLE 1 MODEL 2932J048 ROUGH IN REFERENCE 60 NOMINAL 1524mm 32 NOMINAL 813mm C L DRAIN OUTLINE...

Страница 8: ...r Loading Product Weight 81 gal 307 l Whirlpool Operation Volume Gallons to Overflow Height to Underside of Deck C Dimensions L W H A 17 3 4 451mm B 10 7 8 276mm C 20 1 2 521mm 70 1 4 1784mm x 34 1 4 870mm 71 15 16 1827mm x 34 1 4 870mm L 71 3 4 1822mm W 35 3 4 908mm H 22 1 2 572mm 2940J048 6 x 36 Stratus TABLE 2 MODEL 2940J048 ROUGH IN REFERENCE 72 NOMINAL 1524mm 36 NOMINAL 813mm C L DRAIN OUTLIN...

Страница 9: ...it Interrupter protection are required At initial start up with the power ON push the GFCI test button The reset button should pop out Push this button in to reset If the GFCI fails to operate in this manner there is a ground fault or malfunction indicating the possibility of electrical shock Turn of the power and do not use until the source of the problem has been identifed and corrected The sile...

Страница 10: ...nty IMPORTANT The silentjet whirlpool will NOT operate unless the water level is at least one inch above the highest jet STARTING WHIRLPOOL Press on off button to start whirlpool STOPPING WHIRLPOOL Press on off button again to stop whirlpool AIR VOLUME CONTROL ADJUSTMENTS Water turbulence is determined by the amount of air mixed with the water Rotate the air volume control counterclockwise for mor...

Страница 11: ... Tile Cleaner Windex Cleaner Mr Clean Cleaner Dow Disinfectant Bathroom Cleaner or other cleaning products in aerosol cans HARSH CHEMICALS SHARP AND ABRASIVE OBJECTS SHOULD NEVER BE USED ON ACRYLIC SURFACES Do not use wire brushes knives or sharp objects to remove stains or other surface blemishes Use of abrasive cleaners or powders will dull the surface If the glossy surface loses its sheen dulle...

Страница 12: ...or returning products for repairs or replacement under this limited warranty and labor or other costs incurred in connection with product removal or installation under this limited warranty 6 ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ALL OF WHICH ARE HEREBY EXPRESSLY DISCLAIMED OR THE EXTENSION BEYOND THE DURATION OF THIS LIMITED WARRANTY OF ANY IMPLIED WARRANTIES INCLUDING THOSE OF ME...

Отзывы: