FREE Panel
20/38
6
PARAMETERS
User-parameterization renders the FREE Panel EVP fully configurable.
be changed using:
Keys on the EVP front panel
PC and FREE Studio software
The following sections provide a detailed analysis of each parameter, divided into categories (folders).
6.1
Table of parameters
The
following table
contains all the device configuration
available in FREE Studio Device and in the
DIAGNOSTICS (DIA) /
menu
Description of columns:
This indicates the
of the FREE Studio Device
containing the parameter in question
A group of these
in the DIAGNOSTICS (DIA) menu
Refer also to the following table:
(x) if present (loaded to EVP)
The local menu - if present (uploaded to EVP) - is defined with the Network
This indicates the
used to
Indicates the address of the modbus register containing the resource to be accessed.
Indicates whether the device
MUST
be rebooted after the parameter has been changed.
Y=YES the device
MUST
be rebooted to save the change.
N=NO the device DOES NOT need to be rebooted after changing the parameter
Indicates if resources are read/write, read-only or write-only:
R
The resource is read-only
W
The resource is write-only
RW The
resource
be both read and written to
Indicates the size of the data in bits.
When the field indicates “-1”, the value read by the register requires conversion, because the value represents a number
with a sign. In other cases the value is always positive or null.
To carry out the conversion, proceed as follows:
If the value in the register is between 0 and 32.767, the result is the value itself (zero and positive values)
If the value in the register is between 32.768 and 65.535, the result is the value of the register – 65.536 (negative
values)
Describes the interval of values that
be assigned to the parameter. It
be correlated with other instrument
(indicated in the parameter
).
Indicates the factory setting for the standard model of the instrument.
Unit of measure for values converted according to the rules indicated in the
column
The unit of measure shown is an example only, as it may change depending on the application (e.g.
in °C/bar could also have %RH)
6.1.1
Table of parameters
(See next page)
FOLDER
EVP
EVP
DIA
ACKNOWLEDGEMENT
x -
AI CALIBRATION
x -
x -
ON-BOARD
x -
ON-BOARD
x x
x
x
x
x
All
Buzzer:
x
x
x
x
HMI remote 1 (rem1)
x
(x)
…
x
(x)
HMI remote 10 (rem10)
x
(x)
LABEL
VAL PAR ADDRESS
RESET (Y/N)
R/W
DATA SIZE
CPL
RANGE
DEFAULT
U.M.
Содержание FREE Panel EVP 3300/C