dE 

Defrost termination temperature 

-50

90

 

-50

90

 

Pr1 

id 

Defrost cycle 

0

99hour 

8   

Pr1 

Md 

The maximum time of defrost 

1

99min 

20 

Pr1 

dF 

Defrost status display 

rt

 : Display cabinet temperature 

It 

: Display start-defrost cabinet 

temperature   

St : Display temperature setting 
value 

dF

 : Display 

“dF” 

it 

Pr2 

AU 

Cabinet temperature upper limit 
alarm value 

(AL+1)

99

 

(AL+1)

99

 

99 

Pr1 

AL 

Cabinet temperature lower limit 
alarm value 

-50

(AU-1) 

-50

(AU-1) 

-50 

Pr1 

Ad 

Temperature alarm delay 

0

99min 

15   

Pr2 

dA 

  Exclusion of temperature alarm 

at startup 

0

99min 

90 

Pr2 

   

7. FRONT PANEL COMMANDS

 

Key 

Function 

Button action 

Indicator light 

  SET 

To display target set point 

Press 

and 

release 

immediately 

  light 

Set point value 

Push  the  key  for  more 
than 2 seconds 

Set recording light 

Save  the  set  point  and  exit  the 
setting mode 

Press the response 

Set Light is off 

In  programming  mode  it  selects  a 
parameter 

Press the response 

Set recording light 

SET+

▼  To enter in programming mode 

Pressing the keys for 3s  Set recording light 

SET+

▲ 

To  return  to  room  temperature 
display     

Press the response 

Set Light is off 

   

▲ 

In programming mode it browses 

the parameter codes or increases 

the displayed value 

Press the response 

Set recording light 

Upload the data to copy card   

Pressing the keys for 1s 

Success  of 

“uP”

Failure of   

"Er” 

   

▼ 

In programming mode it browses the 
parameter  codes  or  decreases  the 
displayed value 

Press the response 

Set recording light 

Содержание ECS-10HT1

Страница 1: ...surement accuracy 40 50 1 50 70 2 the others 3 or 40 99 2 the others 6 4 Temperature controlling range 50 99 5 Power supply 220 10 VAC 50 60Hz 6 power consumption 3W 7 Rated current of the relays Refr...

Страница 2: ...Cabinet sensor calibration 9 9 9 9 20 20 0 Pr1 P2 Evaporator sensor selection y Enable n Forbidden y Pr1 oE Evaporator sensor calibration 9 9 9 9 20 20 0 Pr2 od Outputs activation delay at start up 0...

Страница 3: ...light SET To display target set point Press and release immediately light Set point value Push the key for more than 2 seconds Set recording light Save the set point and exit the setting mode Press th...

Страница 4: ...display its value 3 Use or to change its value 4 Press SET to store the new value and move to the following parameter 5 To exit Press SET or wait 15s without pressing a key HIDDEN MENU the second leve...

Страница 5: ...up to od value if the cabinet temperature is lower than the set point heating will start If the cabinet sensor is fault the compressor will run and stop according to the set time running time Cy and s...

Страница 6: ...cabinet temperature is below the AL set point Ad and dA all finished it will display LA when the temperature is higher than the AL the alarm will stop 9 Hot key 1 Upload Program one controller with t...

Страница 7: ...hout electricity cut off Warning Prohibit using this unit under the environment of over damp high temp strong electromagnetism interference or strong corrosion Notice 1 The power supply should conform...

Страница 8: ...a proper distance 3 When evaporator sensor is installed the sensor should be well connected with the copper tube which is 5cm away from evaporator inlet...

Отзывы: