dE
Defrost termination temperature
-50
~
90
℃
-50
~
90
℉
2
Pr1
id
Defrost cycle
0
~
99hour
8
Pr1
Md
The maximum time of defrost
1
~
99min
20
Pr1
dF
Defrost status display
rt
: Display cabinet temperature
It
: Display start-defrost cabinet
temperature
St : Display temperature setting
value
dF
: Display
“dF”
it
Pr2
AU
Cabinet temperature upper limit
alarm value
(AL+1)
~
99
℃
(AL+1)
~
99
℉
99
Pr1
AL
Cabinet temperature lower limit
alarm value
-50
℃
~
(AU-1)
-50
℉
~
(AU-1)
-50
Pr1
Ad
Temperature alarm delay
0
~
99min
15
Pr2
dA
Exclusion of temperature alarm
at startup
0
~
99min
90
Pr2
7. FRONT PANEL COMMANDS
Key
Function
Button action
Indicator light
SET
To display target set point
Press
and
release
immediately
light
Set point value
Push the key for more
than 2 seconds
Set recording light
Save the set point and exit the
setting mode
Press the response
Set Light is off
In programming mode it selects a
parameter
Press the response
Set recording light
SET+
▼ To enter in programming mode
Pressing the keys for 3s Set recording light
SET+
▲
To return to room temperature
display
Press the response
Set Light is off
▲
In programming mode it browses
the parameter codes or increases
the displayed value
Press the response
Set recording light
Upload the data to copy card
Pressing the keys for 1s
Success of
“uP”
、
Failure of
"Er”
▼
In programming mode it browses the
parameter codes or decreases the
displayed value
Press the response
Set recording light