![Elitech ECS-10HT1 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/elitech/ecs-10ht1/ecs-10ht1_instruction_2390823001.webp)
ECS-10HT1 Temperature controller instruction
1.Product Overview
ECS-01HT1 Universal temperature controller can convert Fahrenheit, Celsius display display,
switching cooling / heating mode. The allocation of cabinet temperature sensor and defrosting control
sensor. Optional defrost relay output and copy card function.
2.operation and display panel
3.Specifications and dimensions
Installation dimension : 71mm×29mm Controller size : 78.5mm×34.5mm×74mm
4.Technical parameters
1
)
Measuring range : -50
~
99
℃
/
℉
(only refers to the sensor calibration value is set to 0)
2
)
Temperature resolution : 9.9
~
-9.9 , 0.1
℃
/
℉
, the others,1
℃
/2
℉
3
)
Measurement accuracy : -40
℃
~
50
℃
, ±1
℃
, 50
℃
~
70
℃
, ±2
℃
, the others : ±3
℃
or -40
℉
~
99
℉
, ±2
℉
, the others : ±6
℉
4
)
Temperature controlling range : -50
~
99
℃
/
℉
5
)
Power supply : 220±10%(VAC) , 50/60Hz
6
)
power consumption : <3W
7
)
Rated current of the relays :
Refrigeration : 30A/220VAC , it can directly drive 1.5 HP (220VAC) compressor , single phase
17A/220VAC , it can directly drive 1.0HP (220VAC) compressor , single phase
Defrost: 10A/220VAC( suggest connect the max 1.4 KW electric heating wire)
8) Front panel water proof : IP65
9
)
The back shell water proof : None
10) Operation condition : 0
℃
~
55
℃
11) Storage condition : -25
℃
~
75
℃
,
12) Relative humidity : 20%
~
85% (relative humidity )
5.Indicator light status description
Indicator light
Symbol
Status
Meaning
Setting
set
On
Parameter settings
Off
working order
Compressor
On
Cooling / heating
Off
Cooling / heating stoped
Flashing
Cooling / heating delay