  ECS-10HT1 Temperature controller instruction 

 

1.Product Overview 

        ECS-01HT1 Universal temperature controller can convert Fahrenheit, Celsius display display, 

switching cooling / heating mode. The allocation of cabinet temperature sensor and defrosting control 

sensor. Optional defrost relay output and copy card function. 

2.operation and display panel 

 

3.Specifications and dimensions 

    Installation dimension : 71mm×29mm                          Controller size : 78.5mm×34.5mm×74mm 

 

4.Technical parameters 

    1

Measuring range : -50

99

/

 (only refers to the sensor calibration value is set to 0) 

    2

Temperature resolution : 9.9

-9.9 , 0.1

/

 , the others,1

/2

 

    3

Measurement accuracy : -40

50

 , ±1

 , 50

70

 , ±2

 , the others : ±3

 

                                                  or -40

99

, ±2

 , the others : ±6

 

    4

Temperature controlling range : -50

99

/

 

    5

Power supply : 220±10%(VAC) , 50/60Hz 

    6

power consumption : <3W   

    7

Rated current of the relays :   

          Refrigeration : 30A/220VAC , it can directly drive 1.5 HP (220VAC) compressor , single phase 

                                            17A/220VAC , it can directly drive 1.0HP (220VAC) compressor , single phase 

            Defrost: 10A/220VAC( suggest connect the max 1.4 KW electric heating wire) 

    8)    Front panel water proof : IP65 

    9

The back shell water proof : None   

    10) Operation condition : 0

55

   

    11) Storage condition : -25

75

    12) Relative humidity : 20%

85% (relative humidity ) 

 

5.Indicator light status description 

Indicator light 

Symbol 

Status 

Meaning 

Setting 

set 

On 

Parameter settings 

Off 

working order 

Compressor 

 

On 

Cooling / heating 

Off 

Cooling / heating stoped 

Flashing 

Cooling / heating delay 

Содержание ECS-10HT1

Страница 1: ...surement accuracy 40 50 1 50 70 2 the others 3 or 40 99 2 the others 6 4 Temperature controlling range 50 99 5 Power supply 220 10 VAC 50 60Hz 6 power consumption 3W 7 Rated current of the relays Refr...

Страница 2: ...Cabinet sensor calibration 9 9 9 9 20 20 0 Pr1 P2 Evaporator sensor selection y Enable n Forbidden y Pr1 oE Evaporator sensor calibration 9 9 9 9 20 20 0 Pr2 od Outputs activation delay at start up 0...

Страница 3: ...light SET To display target set point Press and release immediately light Set point value Push the key for more than 2 seconds Set recording light Save the set point and exit the setting mode Press th...

Страница 4: ...display its value 3 Use or to change its value 4 Press SET to store the new value and move to the following parameter 5 To exit Press SET or wait 15s without pressing a key HIDDEN MENU the second leve...

Страница 5: ...up to od value if the cabinet temperature is lower than the set point heating will start If the cabinet sensor is fault the compressor will run and stop according to the set time running time Cy and s...

Страница 6: ...cabinet temperature is below the AL set point Ad and dA all finished it will display LA when the temperature is higher than the AL the alarm will stop 9 Hot key 1 Upload Program one controller with t...

Страница 7: ...hout electricity cut off Warning Prohibit using this unit under the environment of over damp high temp strong electromagnetism interference or strong corrosion Notice 1 The power supply should conform...

Страница 8: ...a proper distance 3 When evaporator sensor is installed the sensor should be well connected with the copper tube which is 5cm away from evaporator inlet...

Отзывы: