ELIS PLZEŇ a. s.
Design, Assembly and Service Manual
Page 14 of 32
Electromagnetic flowmeter FLONET FN50xx.1
ELIS PLZEN a. s., Lucni 425/15, 301 00 Plzen, Czech Republic, Phone: +420/377 517 711, fax: +420/377 517 722
Es90716K
4.1.6. Dimensions of flanged sensor IS0.Mxx (for heat meters)
l
L
d
A
DN
D
M
6
Dimensions of flanged sensor according to DN
Flanges according to the norm EN 1092-1
DN
D
d
A*
L
l
Weight
[ kg ]
15
95
62
x
200
66
2
20
105
62
x
200
66
2,5
25
115
72
187
200
96
3
PN40
32
140
82
206
200
96
4
40
150
92
216
200
96
4
50
165
107
230
200
96
6
65
185
127
251
200
96
9
80
200
142
267
200
96
14
PN16
100
220
162
287
250
96
16
125
250
192
317
250
126
19
150
285
218
347
300
126
25
200
340
274
405
350
211
41
PN10
250
395
370
487
450
211
54
300
445
420
542
500
320
77
350
505
480
591
550
320
92
400
565
530
649
600
320
116
500
670
640
759
600
320
167
600
780
760
877
600
320
288
700
895
880
997
700
420
356
PN6
800
975
960
1107
800
420
427
* Height is considered without the electronic unit, without the junction box respectively. Weight of flow