Troubleshooting
Verify that you are using the appropriate power supply adapter. Do
not use the power adapter with DC output higher than the power
rating of the device.
Select the proper UTP/STP cable to construct your network. Use
unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable
for RJ-45 connections: 100
Ω
Category 3, 4 or 5 cable for 10Mbps
connections, 100
Ω
Category 5 cable for 100Mbps connections.
Insure the length of any twisted-pair connection does not exceed 100
meters (328 feet).
Diagnosing LED Indicators:
The Switch can be easily monitored
through panel LED’s. The LED’s will provide an easy way of
detecting power or communication problems.
If the Industrial switch LED indicators function normal and the
connected cables are correct but the packets still cannot transmit,
please check your system’s Ethernet devices’ configuration or status.
The Ping test is a common method to check Ethernet devices
connections on the network.