elink PWELINK RM P2 RJ45EC REAR Скачать руководство пользователя страница 1

Port LEDs

Amber. Intermittent blinking indicates valid link to 

other device. Off indicates link is down.

LCD 

Backlight

Will light up when using the front encoder knob. When 

set to Identify mode using Pathscape, the backlight 

will flash.

PWELINK RM P2 RJ45EC REAR

eLink Lighting Protocol Router

Installation 

Guide

11/09/21

The Pathway eLink™ Lighting Protocol Router is designed for 

entertainment DMX-over-Ethernet systems.
The eLink Lighting Protocol Router is intended specifically for signal 

routing between distinct Local Area Networks, while maintaining 

security and isolation between them.
The eLink is able to convert between several popular DMX-over-

Ethernet protocols, including 

Pathport Protocol

sACN (E1.31)

Art-Net

Strand ShowNet

, and 

Pathway ssACN (Secure sACN)

The eLink can also optionally loop back converted protocols on a 

single network, when physical isolation of data is not needed.
The  eLink  is  easily  configured  and  upgraded  using  the  freely 

available software tool, Pathscape. It is also configurable using the 

Front Panel UI, which consists of the LCD and rotary pushbutton 

encoder. 

NOTE

 that some features are not available if configuring 

the device solely with the front panel.

POWER

The eLink can be powered via a Power-over-Ethernet (PoE) source, 

such as a VIA PoE Switch. The PoE source must be connected to 

the Primary Port.

The eLink may be powered via DC Power supply between 24-48 

VDC, center positive, 2.5mm barrel connector. A screw terminal is 

provided to connect the device to earth ground.

ETHERNET

The eLink has two RJ45 etherCON ports on the rear of the device: 

the Primary Port, and Secondary Port. The Primary Port should 

be connected to the main/source network (and PoE source). The 

Secondary Port should be connected to the downstream network.

Each etherCON port has a status LED: to the left of the Primary 

Port, and to the right of the Secondary Port. The LEDs will light 

up amber when a link is established, and will flash when there is 

network activity. If the LEDs are off, there is no active link.

CONTACT CLOSURE INTERFACE (CCI)

There is a dry contact closure input on the rear panel. Shorting the 

two terminals will activate the associated function. The Contact 

Closure can activate DMX Hold on a per Data Path basis, and more 

functions may be added in future firmware updates.

Disconnect all power before proceeding with installation.
Securely mount device to rack unit, if applicable. Connect the DC 

input or PoE source to the Primary Port. The eLink will boot up, 

which may take 15-20 seconds.
Attach network cable to downstream network (Secondary Port). 

Open 

Pathscape

 on a PC on the same network as the device. Add 

the eLink to a 

Security Domain

.

The system is now ready for configuration and testing.

For detailed instructions on operation of the eLink, please see 

the eLink manual available on the Pathway website.

All field configuration of eLink is recommended to be done with 

Pathscape

 software.

Download  the  software  from 

www.pathwayconnect.com

 and 

install.

Before  configuring  and  using  the  eLink,  you  must  add  it  to  a 

Security Domain

 using Pathscape.

Set computer’s IP to a static address in the 10.x.x.x range, with 

a subnet mask of 255.0.0.0 and default gateway of 10.0.0.1. No 

configuration of the computer’s DNS settings should be required. 

Plug into the eLink and launch the software. Discovery will be 

automatic.

Refer to additional eLink and Pathscape documentation for 

description of configuration options

.

OVERVIEW

CONNECTIONS

STATUS INDICATORS

INSTALLATION

CONFIGURATION

2.5 mm

24-48VDC 

AUX INPUT

CC1

PRIMARY

PORT - PoE

SECONDARY

PORT

Contact Closure 

Input

Primary Ethernet 

Port (1Gbps - PoE)

Auxiliary 24-48VDC

Input

Secondary Ethernet 

Port (100Mb - connect 

to downstream 

network)

Отзывы: