S A F E T Y   G U I D E L I N E S

This unit may “pop” the fuse if the maximum allotted load of 3 amps is reached.

•  To reduce the risk of electrical shock or fire, do not expose this unit rain or moisture.

•  Do not spill water or other liquids into or on to your unit.

•  Do not attempt to remove or break off the ground prong from the  electrical cord. This prong is 

used to reduce the risk of electrical shock and fire in case of an internal short. 

•  Do not attempt to operate this unit if the power cord has been frayed or broken.

•  Disconnect from main power before making any type of connection.

•  Do not remove the cover under any conditions. There are no user serviceable parts inside.

•  Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” 

(15cm) between this device and a wall.

•  Do not attempt to operate this unit if it has been damaged in any way.

•  This unit is intended for indoor use only. Use of this product outdoors voids all warranties.

•  During long periods of non-use, disconnect the unit’s main power.

•  Always mount this unit in safe and stable matter.

•  Power cords should be routed so they are not likely to be walked on, pinched by items placed 

upon or against them.

•  Cleaning - The fixture should be cleaned only as recommended by the manufacturer. See the 

Maintenance Guidelines section of this manual for cleaning details.

•  Heat - The appliance should be situated away from heat sources such as radiators, heat regis-

ters, stoves, or other appliances (including amplifiers) that produce heat.

•  The fixture should be serviced by qualified service personnel when:

A.  The power-supply cord or the plug has been damaged.

B.  Objects have fallen, or liquid has been spilled into, the unit.

C.  The unit has been exposed to rain or water.

D.  The unit does not appear to operate normally or exhibits a marked change in performance.

7

Содержание FUR128

Страница 1: ...Furious Three RG Furious Three RG User Manual SKU FUR128 UPC 818651029314 ...

Страница 2: ...ator Lighting and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of...

Страница 3: ...ion 4 Limited Warranty USA Only 5 Safety Guidelines 6 Laser Warnings and Safety 8 Maintenance Guidelines 10 DMX Setup 11 Overview 14 Installation Instructions 15 System Menu 17 DMX Traits 19 Dimensional Drawing 23 Specifications 24 3 ...

Страница 4: ...nty or not must be freight pre paid and accompa nied by a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R A number must also be written down on a piece of paper and included in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice ...

Страница 5: ...refur bished parts and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 20...

Страница 6: ...NES IN THIS MANUAL VOID THE MANUFACTURER S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND OR REPAIRS NEVER TOUCH FIXTURE DURING OPERATION AS IT MAY BE HOT ALWAYS REPLACE FUSES WITH REPLACEMENTS OF THE SAME TYPE KEEP FLAMMABLE MATERIALS AWAY FROM THESE DEVICES INDOOR DRY LOCATIONS USE ONLY DO NOT EXPOSE DEVICES TO RAIN AND OR MOISTURE NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE OR LASER RETI...

Страница 7: ...t to operate this unit if it has been damaged in any way This unit is intended for indoor use only Use of this product outdoors voids all warranties During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power cords should be routed so they are not likely to be walked on pinched by items placed upon or against them Cleaning The fixture shou...

Страница 8: ... aircraft This is a federal offense Never point un terminated laser beams into the sky Do not expose the output optic aperture to cleaning chemicals Do not use laser if the laser appears to be emitting only a few beams Do not use the laser if the housing is damaged the housing is open or if the optics appear dam aged in any way Never open the laser housing The high laser power levels inside of the...

Страница 9: ...9 L A S E R W A R N I N G S A N D S A F E T Y ...

Страница 10: ... to the following points during routine inspections A detailed review should be performed by an approved electrical engineer every three months to make sure the circuit contacts are in good condition in order to prevent overheating Be sure all screws and fasteners are securely tightened at all times Loose screws may fall out during normal operation resulting in damage or injury as larger parts cou...

Страница 11: ...DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Oper...

Страница 12: ...ior A terminator is a 110 120 ohm 1 4 watt resistor which is connected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line Using a cable terminator will decrease the chances of erratic behavior 5 Pin XLR DMX Connectors Some manufacturers use 5 pin DMX 512 data cables for DATA trans m...

Страница 13: ...ch individual fixture Setting all fixtures to the same DMX address will cause all fixtures to react in the same way In this case please note that changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel num ber you have set based on the quantity of DMX channels of each fixture T...

Страница 14: ...nd Indicator 5 DMX Indicator 6 Display Screen 7 Auto Mode Indicator 8 Secondary Mode Indicator 9 Sound Sensitivity Adjustment 10 DMX Out 11 DMX In 12 Enter Button 13 Down Button 14 Up Button 15 Function Button 16 Laser Safety Switch 17 Fuse 18 Power In 19 Power Out 20 Safety Cable Loop 14 ...

Страница 15: ...TRUCTURE OR CEILING A PROFESSIONAL EQUIPMENT INSTALLER MUST BE CONSULTED TO DETERMINE WHETHER THE METAL TRUSS STRUCTURE OR CEILING IS PROPERLY CERTIFIED TO SAFELY HOLD THE COMBINED WEIGHT OF THE LIGHT FIXTURE CLAMPS CABLES AND ACCESSORIES BEFORE MOUNTING DEVICES TO ANY SURFACE OR STRUCTURE MAKE SURE THE SUR FACE OR STRUCTURE CAN HOLD A MINIMUM POINT LOAD OF 10 TIMES THE WEIGHT OF THE DEVICES MAKE ...

Страница 16: ...point and attach a separate SAFETY CABLE of the appropriate safety rating to the safety cable rig ging point SAFETY CABLE ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THAT THE FIX TURE WILL NOT FALL IF THE CLAMP FAILS RIGGING Overhead rigging requires extensive experience including but not limited to calculating working load limits understandin...

Страница 17: ...ntrol but tons located on the back face of the device below the digital display FUNC Press to cycle through main menu options Auto Sound Secd DMX ENTER Press to confirm selection and open up the option sub menu if applicable UP DOWN Press to scroll through menu or sub menu options S Y S T E M M E N U 17 ...

Страница 18: ...irm then adjust sensitivity with Sound Sensitivity Adjustment knob Sou1 Laser RGBWY Sou2 Laser 8x1WLED Sou3 RGBWY 8x1WLED Sou4 RGBWY Sou5 Laser Sou6 8x1WLED Secd When selected the unit will fol low the movements of a desig nated primary unit NOTE A flashing display screen indicates a poor con nection to the primary unit Please check the cable connections DMX D001 D506 NOTE A flashing display scree...

Страница 19: ... 70 84 Aut4 85 99 Aut5 100 114 Aut6 115 129 Sou0 130 144 Sou1 145 159 Sou2 160 174 Sou3 175 189 Sou4 190 204 Sou5 205 220 Sou6 221 255 DMX Mode 2 LED Operation 0 9 No Function 10 14 Red 15 19 Green 20 24 Blue 25 29 Yellow 30 34 White 35 39 Red White 40 44 Red Green 45 49 Green Blue 50 54 Blue Yellow 55 59 Yellow White 60 64 Green White 65 69 Green Yellow CONTINUED ON NEXT PAGE ...

Страница 20: ...llow 120 124 Green Blue White 125 129 Green Yellow White 130 134 Blue Yellow White 135 139 Red Green Blue Yellow 140 144 Red Green Blue White 145 149 Green Blue White Yellow 150 154 Red Green White Yellow 155 159 Red Blue White Yellow 160 164 Red Green Blue Yellow White 165 209 Automatic single colors only 210 255 Automatic two colors at a time 3 0 255 Automatic Speed slow to fast when CH2 is set ...

Страница 21: ... slow to fast 100 109 Picture 10 slow to fast 110 255 On 6 Laser 0 9 No Function 10 49 Red On 50 89 Green On 90 129 Red and Green Alternating Strobe CH7 must be set to appropri ate value 130 169 Red On Green Strobe CH7 must be set to appropriate value 170 209 Green On Red Strobe CH7 must be set to appropriate value 210 255 Red and Green Strobe CH7 must be set to appropriate value 7 Laser Strobe 0 ...

Страница 22: ...T S 22 Eliminator Furious Three RG DMX Traits Software Version 1 0 CHANNEL DMX VALUE DESCRIPTION 9 Laser Rotate 0 4 Stop 5 127 Rotate Clockwise slow to fast 128 133 Stop 134 255 Rotate Counter Clockwise slow to fast ...

Страница 23: ...23 D I M E N S I O N A L D R A W I N G ...

Страница 24: ...r Red Green laser diodes 4 control mode DMX Sound Active Auto Primary Secondary 4 button LED display menu 9 DMX channels Electronic dimming 0 100 3 pin DMX In Out IEC AC In Out connectors to daisy chain power Laser On Off with safety key Safety eye on rear panel Built in microphone with sensitivity potentiometer With wired digital communication network Power Draw 40W max Dimensions 11 8 x 12 25 x ...

Страница 25: ...25 ...