How to set the slave monitor address

Maximum 4 monitors can be connected in one apartment,one master monitor together 

with 3 slave monitors, so you should set the address correctly.(note:must have one 

monitor to be set as master monitor)

The code of 8000 is used to set the master monitor.

The code of 8001 is used to set the  first slave monitor .

The code of 8002 is used to set the  second slave monitor .

The code of 8003 is used to set the  third slave monitor .

How to set the  monitor panel on 

In default mode,when receive a calling,the master and slave monitors will ring at the 

same time,and just the master monitor can display the image while the slave monitors 

can not.But the settings can be changed,you can set the master monitor and all the slave 

monitors to panel on at the same time when receiving a call, just input the code number 

of 8006  on each slave monitor.















The system offers two methods of date and time.

The code number of 8008 is used to set the date format as month/date/year

The code number of 8009 is used to set the date format as date/month/year

The code number of 8012 is used to set the time format as 12 hour system

The code number of 8013 is used to set the time format as 24 hour system

How to set date and time format

-11-

Содержание EVD2-60IN

Страница 1: ...2 WIRE INTERCOM SYSTEM EVD2 60IN ENGLISH Please read this manual carefully before using the product and keep it well USER MANUAL...

Страница 2: ...tion Bit State Description DIP3 1 2 3 ON 1 2 3 ON Set to ON When the montior is at the end of the line or connected to a DBC4S LCD screen Display the visitors image Unlock button Press to release the...

Страница 3: ...r 90 seconds After finishing communication press TALK MON button again or touch icon to end the communication If nobody answers the phone the screen will be turned off automatically after 30 seconds 0...

Страница 4: ...if the system connect 2 wire camera via camera controller press the camera 1 2 3 4 to monitor the camera you want press icon to exit and enter main menu page 5 Intercom Function 1 Inner Broadcast If...

Страница 5: ...or when the Guard Unit Monitor answers the call conversation with the guard person is started 6 Video Picture Memory 01 Jim Zhang 02 Calo Liu 03 Jacko Zhang 04 Philips Chen 05 Hebe Zhang 06 Tony Li Na...

Страница 6: ...8 20 54 Smith 06 12 11 06 Vincent Yang 05 29 08 39 Allen Chen 05 27 21 43 Hebe Zhang 04 20 13 16 Ben Wu Call Record 01 05 06 23 15 22 Calo Liu 06 18 20 54 Smith 06 12 11 06 Vincent Yang 05 29 08 39 Al...

Страница 7: ...rt modes 1 Don t Transfer calls from outdoor station will not be diverted 2 If No Answer outdoor station calls indoor monitor firstly if nobody answer the call within 30 seconds the call will be diver...

Страница 8: ...taircase light the staircase light will be turned off automatically 11 Basic Setup Instructions Sounds Settings Touch icon on main menu page or on door camera switching mode page then select Sounds it...

Страница 9: ...the setting and return main menu page Note You can set your own time you can also synchronize the system time Rename Monitor Time Settings Touch icon on main menu page or on door camera switching mod...

Страница 10: ...the modifications will be performed immediately after the operation Touch the window of image to exit the adjust page Screen and Volume Adjustment The restore to default function allows the user to r...

Страница 11: ...00 Copy Pictures To SD Memo Information SD Card Video Capacity Video Usage Flash Image Capacity 0118 Image Usage 0000 Format SD Card And Restart About Local Address 00 00 Video Standard AUTO System Ve...

Страница 12: ...lling the master and slave monitors will ring at the same time and just the master monitor can display the image while the slave monitors can not But the settings can be changed you can set the master...

Страница 13: ...or the monitor Each monitor should be assigned an address in the system total 32 addresses can be configured the code number of 8200 to 8231 is used to controlled the address of 00 to 31 Please refer...

Страница 14: ...soft cotton cloth please do not use the organic impregnant or chemical clean agent If necessary please use a little pure water or dilute soap water to clean the dust 3 Image distortion may occur if th...

Страница 15: ...Note 14...

Страница 16: ...The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved 2 WIRE INTERCOM SYSTEM EVD2 60IN...

Отзывы: