![Elikon EVD2-10OU Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/elikon/evd2-10ou/evd2-10ou_user-manual_2389072009.webp)
When Monitor quantity < 20
When Monitor quantity >20
Bit state
User code
code=0
code=1
code=2
code=3
code=4
code=6
code=7
code=8
code=9
code=10
code=11
code=12
code=13
code=14
code=15
code=5
Bit state
User code
Bit state
User code
Cable Requirements
The maximum distance of the wiring is limited in the DT system. Using different cables may also
affect the maximum distance which the system can reach.
Specification
• Power Supply:DC 24V
• Power Consumption:Standby 60mA;
W
orking status 200mA
• Lock Power Supply:12Vdc, 300mA(Internal Power)
• Working Temperature: -10ºC ~ +45ºC
• Wiring: 2 wires,non-polarity
• Dimension:137(H)x49(W)x28(D)mm
Precaustions
• Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent.
If necessary, please use a little pure water or dilute soap water to clean the dust.
• The unit is weather resistant. However do not spray high pressure water on access control keypad
directly. Excessive moisture may cause problems with the unit.
• You must use the right adaptor which is supplied by the manufacture or approved by the manufacture.
• Pay attention to the high voltage inside the products, please refer service only to a trained and qualified
professional.
Cable Usage
A
B
C
Twisted cable 2x0.75 mm
2
60
60
30
80
80
40
Twisted cable 2x1 mm
2
Cable Usage
A
B
C
Twisted cable 2x1 mm
2
70
30
20
70
50
30
Twisted cable 2x1.5 mm
2
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
1 2
3 4 5
6
ON
The farest monitor
B
A
C
DBC-4S
monitor
monitor
monitor
with two or four monitors
AC~
PC6
Note:If the monitor has been specified
the distance,refer to the parameter.
-9-