2. Brief Description 

 

    The  electronic  scales  from  series  EVLplus  xx  LM,  LM,  LT,  BT,  are  precise  measuring  devices  for 
determining the weight of goods in retail stores and warehouses. 

   All scales from series ELVplus are designed to work in temperature range from -10°C to +40°C and 

to work without external power supply for up to 100 hours.  

  The  scales  provide  accurate  measurement,  user-friendly  reading  indicators  from  a  double  sided 

digital LCD indicator, automatic price calculation, automatic Zero set and Tare functions. 
     All  the scales  are  equipped  with  interface  RS232  for  connection  with  other external  devices such 
as PC, cash registers, labeling printers.  
 

3. Main Functions 

 

  Weight determination of the weighed products 

  Input of the price per 1 kg  

  Storing data for price, Tare, name, expiration date and est. of more than 2,000 articles 

  Displaying the information for the weight, price per kg and total value of the product on two 

widow displays one for the user and one for the customer 

  Redirecting the information to PC, cash registers, label printers 

  Sound signals 

 

4. Technical Data 

 
4.1. General data for scales from series EVLplus 

1.  Dimensions:         380 

х

 300 

х

 129 mm 

2.  Shipping weight:   5 kg 
3.  Display: 

 

For models LM, LT:  

o

 

Operator’s: LCD - 6 positions, 3 lines 

o

 

Client’s:      LCD - 6 positions, 3 lines 

 

For models BM, BT:  

o

 

Operator’s: LCD - 6 positions, 3 lines – 1 peace 

o

 

Client’s:      LCD - 6 positions, 1 line – 3 peaces 

4.  Classified Accuracy  

   

 

According to the Bulgarian State Standard EN 45501:2001 

5.  Error Limitations according to the Bulgarian State Standard EN 45501:2001 
6.  Number of check divisions: n = 3,000 
7.  Working Conditions 

-

 

Power Supply:     - Built-in battery 6 V / 5 Ah 

       - AC adapter ~ 220 V / ~ 14 V 

-

 

Maximum Power Consumption: < 4 VA 

-

 

Operating Temperature:             -10°C to +40°C 

-

 

Air Humidity:                            20 % to 80 % 

-

 

Air Pressure:                            84 to 107 kPa 

-

 

Safety Requirement – according to Bulgarian State Standard 14374-84 

8.  Metal platter  

-      Size 300 

х

 250 mm 

III 

Содержание EVLplus xx B?3

Страница 1: ...cription 4 3 Main functions 4 4 Technical data 4 5 Scale Overview 5 6 Preparing for use 6 7 Installation instructions 7 8 Operation modes 7 8 1 Weighting Mode 8 8 2 Counting Mode 18 8 3 Labeling and P...

Страница 2: ...Scale Models Series EVLplus EVLplus xx L 3 EVLplus xx L 6 EVLplus xx B 3 EVLplus xx B 6...

Страница 3: ...Elicom Electronic Ltd 1 Warranty Card...

Страница 4: ...Displaying the information for the weight price per kg and total value of the product on two widow displays one for the user and one for the customer Redirecting the information to PC cash registers l...

Страница 5: ...g EVL 6 6 kg 40 g minus 6 kg 2 g EVL 6 15 6 15 kg 40 g minus 15 kg 2 5 g EVL 15 15 kg 100 g minus 15 kg 5 g EVL 15 30 15 30 kg 100 g minus 30 kg 5 10 g EVL 30 30 kg 200 g minus 30 kg 10 g Model Extern...

Страница 6: ...in appendix 8 from the Regulation on the left side of the scales is placed a label with serial number meteorological characteristics of the scale CE logo for correspondence and the year of which the...

Страница 7: ...switched on 5 Turn On the scale by pressing the ON OFF button After this operation an automatic check is performed on all the indicators by indicating all the figures from 0 to 9 Wait for 10 minutes...

Страница 8: ...ently being weighted is considered as tare The load indication is set to zero and the scale starts indicating net weight which is marked by a NET icon If a load lighter than the Tare is being weighted...

Страница 9: ...ample pressing the 3 12 button will call out the price for the article with number 3 If before that the is pressed then the button 3 12 will call out the price for the article with number 12 6 Button...

Страница 10: ...the scale does not calculate Total price 8 1 3 Weighing an article using previously set price The article is stored under number 3 and no Tare is considered for example oranges The load is placed By...

Страница 11: ...re is shown with a negative sign and the T symbol is shown in the left part of the display 8 1 4 Weighing an article considering Tare value for example oranges in a pot The pot or other object for Tar...

Страница 12: ...ter The display shows the net weight of the weighed product with the total price calculated The NET sign shows that the scale works with Tare and at the moment is shown the net weight During a loaded...

Страница 13: ...re Note 2 If a Tare is set with the key the call of an article with previously set Tare doen t change the weighed tare 8 1 5 Accumulating totals customer s bill Note This option is factory disabled To...

Страница 14: ...e customer s bill 8 1 5 2 Accumulated totals to the client s bill By pressing the MR the scale is switching in mode to view the Customer s Bill By pressing the MR repeatedly all the accumulated totals...

Страница 15: ...in the client s bill To go back to Weighing Mode press the C or CP keys 8 1 5 3 To delete a particular sale choose the desired sale by pressing MR To delete press the MC key two times When deleted the...

Страница 16: ...to exit the Client s bill and to continue work 8 1 6 Register of Sales When using the functions of Client s bill see 8 1 5 exit the mode see 8 1 5 4 The Client s bills are accumulated in a Register o...

Страница 17: ...moment Use the MR key to switch the articles on which there are accumulated sums To clear the Register of Sales press the MC key two times when the Register of sales mode is entered When the register...

Страница 18: ...On the line below is displayed Basic number of details Changing the number is done by the numerical keyboard 4 If Tare is used Place the object used for Tare and press to set the Tare 5 Press the CH...

Страница 19: ...ly unloaded in the scale This is done by using Label editor and Parameter editor software offered by the manufacturer Depending on the memory and the modification is possible to set the following data...

Страница 20: ...he label Activate Service mode 2 PRG DW and after that press the PRG key rapidity till rELAb 0 is displayed By pressing from the numeric keyboard change the blinking 0 to 1 Exit with In Weighing Mode...

Страница 21: ...Electronic Scale models EVLplus L 1 BM1 LT1 BT1 21 Double click PRG By continuous pressing of the PRG key is switching to the different functions of the mode...

Страница 22: ...t mode is Programming of price and tare described in detail in p 8 4 3 PRG Voltage of the battery 6 41V Described in p 8 4 5 battery check PRG Calibration mode of the scale PRG Set up of the PC commun...

Страница 23: ...le automatically turns off When turning the scale on after AUTO OFF no initial test is preformed PRG Au0 0 Automatic checking for Zero 0 For value 0 automatic checking for Zero is Disabled For value 1...

Страница 24: ...NG Mode press PRG followed by DW For setting the parameter are used the keys 0 9 C PRG for switching to next parameter CP for switching back to WEIGHING Mode The non numerical fields are changed by C...

Страница 25: ...al time Use PRG set of the date and the time PRG Counter number PRG Operator s number PRG Logical number of the scale in LAN network PRG Enable Disable automatic print of labels To change use C PRG se...

Страница 26: ...3 The access to the parties numbers can be obtained in WEIGHING Mode with unloaded scale by pressing PRG followed by the PRN PRG Enable Disable function Pre labeling to change use C PRG Enable Disabl...

Страница 27: ...IGHING Mode The display shows price and tare for article 1775 If there is no set tare the display for weight is showing the current weight The price of the article is blinking and the display for tota...

Страница 28: ...save the changes and the scale is switching to the next PLU number in this case 122 To go back to WEIGHING Mode press CP at any time to skip the rest of the functions in the SERVICE Mode 8 4 4 Batter...

Страница 29: ...battery icon disappears Continue the charging till the battery voltage reaches close to 6 8V with the adapter turned on 8 5 Connecting to external devices The scale can be connected to PC label printe...

Страница 30: ...and cables for connection are additionally offered by the manufacturer 8 6 Error Mode The error mode is shown by lighted bottom segments lines along the display and a sound signal The Error Mode is i...

Страница 31: ...ox 188 Tel 359 86 820 200 882 255 Fax 359 86 820 555 e mail info elicom bg com OFFICE AND SERVICE 1784 Sofia Bulgaria 131 Tsarigradsko shosse ATM Center fl 4 office 403 Tel 359 2 974 4391 Fax 359 2 97...

Отзывы: