background image

 

 

 
 
 
 

OWNER’S MANUAL 

 
 
 
 

 

Electronic scales Series EVLplus 

 

 

 

 

Model

: Т                                  Model: М                            Model:F 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

Version: 1.10 

Содержание EVLplus BF8 Series

Страница 1: ...OWNER S MANUAL Electronic scales Series EVLplus Model Model Model F Version 1 10...

Страница 2: ...K WITH PLU 11 3 4 1Programming of PLU 11 3 4 2Selling stored PLU 13 3 5 TARE 13 3 5 1Taring an empty container 13 3 5 2Manual Tare 14 3 6 ACCUMULATING 15 3 6 1Accumulating sales 15 3 6 2Review of accu...

Страница 3: ...adapter provided from manufacturer Cleaning of the scale must be performed when scale is off Do not use aggressive cleaning chemicals Use soft brush to clean printer In case of flooding with liquids o...

Страница 4: ...s on the disposal of materials that are hazardous to the environment 1 6 Connecting to mains power Connect the supplied power supply unit to the power connection socket on the underside of the scale P...

Страница 5: ...5 2 2 Models EVLplus xx LT3 EVLplus xx BT3 EVLplus xx LM6 EVLplus xx BM6 EVLplus xx LF8 EVLplus xx BF8...

Страница 6: ...6 2 3 Keyboard Model LT BT Model LM BM Model LF BF...

Страница 7: ...t Selling by pcs PRINT Printing receipt or label models BF LF Adding a sale into client bill when applicable Calling PLU Entering into Programming Programming manual tare Exit menu Reviewing client bi...

Страница 8: ...2 5 Main view Model EVL xx LT1 Description 1 Lower body 2 Weighing platform 3 Upper body 4 Leveler 5 Adjustable legs 6 Keyboard 7 Client display 8 Operator s display 9 Interface RS232 9 8 7 3 6 1 4 2...

Страница 9: ...nal rechargeable battery 6 V 4 Ah by external adapter 220 V 12 V Working temperature 10 C to 40 C Air humidity 20 to 80 Metal platform Dimensions LM BM LT BT 330 250 mm LF BF 260x225mm 2 6 2 Data for...

Страница 10: ...2 Free price input From normal weighing mode place the product on the weighing pan Enter price per kg 2 56EUR keys If a wrong price is inputted clear the price by Enter new price Take the load from t...

Страница 11: ...ramming PLU double press the display is showing the price and tare of the last programmed PLU If there is no programmed tare the display for Tare is showing the current weight The price of the PLU is...

Страница 12: ...isualized The price is blinking Enter the desired price For example 4 75 If you want to program tare place the tare weight on the pan platter and press to save the Tare value The value of the Tare is...

Страница 13: ...tween 10 and 18 example 10 press followed by For all other PLU enter the PLU number followed by The total sum to pay is displayed on the third line on the display 3 5 TARE 3 5 1 Taring an empty contai...

Страница 14: ...con T is indicating that the weight is Tare When scale is free of weight Use to clear the tare Note The Tare is automatically cleared when scale is unloaded when parameter t_clr ON 3 5 2 Manual Tare P...

Страница 15: ...ft to indicate that a sale is stored Place second item enter price to pay and add to accumulation by 3 6 2 Review of accumulated items Press for model LF BF to review accumulated items By pressing for...

Страница 16: ...splay shows the next accumulated sale Now the number of sales is only 1 3 6 4 Deleting accumulation After accumulation is finished the current accumulation is displayed by for model LF BF Press to del...

Страница 17: ...umulation account and deleted account press for model LF BF you can open register of sales The display shows total accumulations Weight turnover for all accumulation accounts The first line shows the...

Страница 18: ...press The middle display shows 0 on the weight line is shown 0 000 and base 2 Place the Base number of details save their weight with 3 Enter the number of details in the middle line display 4 The sca...

Страница 19: ...deactivated by default 3 8 1 Labeling To work with a label printer the labels and the articles PLU need to be previously uploaded in the scale This is done by using Label editor and Parameter editor...

Страница 20: ...followed by Display for price shows 0 000 this means that scale is in pre label mode manual input of price Enter the desired weight by the keyboard and print a label with for model LF BF To the PLU pr...

Страница 21: ...6 41V Calibration menu jumper protected Interface communication setting Interface parity control and other settings ON OFF automatic tare clear after scale unload ON OFF automatic price clear after u...

Страница 22: ...g initial test Value 0 Zero tracking is off Value 1 negative movements are allowed Value 2 both negative and positive movements are allowed Automatic Zero tracking 4 2 Service mode 2 Press the followi...

Страница 23: ...0 1 Yes No changed with Parameter LABEL show the number of label form sent to printer Date and time set up key used to switch from date to time settings Stand number Operator number Scale logic number...

Страница 24: ...24 Activate Deactivate automatic label print change by Label consequence number Activate Deactivate Accumulation function changed by batch number 1 batch number 2 batch number 3...

Страница 25: ...25 Activate Deactivate Pre Labeling function changed by Activating Deactivating Counting mode changed by Calling PLU by PLU PLU1 or by article number Art1 changed by Going back to weighing mode...

Страница 26: ...ter the message batLO the display is turning off automatically When working without adapter the dropping of the voltage is displayed by a battery icon in the left part of the display The company recom...

Страница 27: ...00 7 8 Connection with PC Label printer 7 4800 9 Scales Angel CAS DIBAL For example CASH 42 means speed 9600 for cash register Datecs When connecting to cash register the scales sends inquiry for weig...

Страница 28: ...28 Main office and manufacturing 5th Saedinenie sq Silistra 7500 BULGARIA Tel 359 86 820 200 882 255 fax 359 86 820 555 e mail info elicom bg com www elicom bg com...

Отзывы: