Functional Safety
- 86 -
Ref. 61508 EN 61508 demand
Value, description of references to other chapters
D2.2 g.)
Initiated outputs
D2.2 h.)
Regular test and maintenance
D2.2 i.)
External diagnostics
not applicable
D2.2 j.)
Hardware failure tolerance
Refer to
D2.2 k.)
Type A / Type B classification
Refer to
Table 30: Calculation of
D
for the entire system
Subsystem
X -times
D
(per systems)
D
(total)
Logic (µ-controller in the broad sense)
2
575
1150
Digital Inputs
6 (3 * 2)
17
102
Diagnostics for digital inputs
3
33
99
Position
2
3297
6594
Relays (OC SR1 and SR2)
6
615
3690
Solid State actuator (eSGC)
2
158
316
3.3 V and 2 V supply voltage
2
113
226
12V Relay supply voltage
1
81
81
EMC of main supply
1
32
40
EMC of battery Supply
1
32
40
Voltage supervision (diagnostics)
2
51
102
External watchdog (diagnostics)
1
23
23
CAN
1
30
30
Floor Sensors
2
1
2
Door Zone Output
1
(approx.) 0
0
Miscellaneous
1
8
8
µ-Controller-PINs
2
212
424
total
12927
16.3
Safety Requirements for the Integration of the System
Refer to
8 Constraints for Use (Safety requirements for integration).