Connections
- 54 -
16.2
Pin Assignment
(default assignment – factory settings)
Table 11: Measuring system connections
Table 12: Input connections
Table 13: Output connections
ST1
Incremental Measuring System
ST2 Incremental Measuring System
1 0 V / GND
1
0 V / GND
2 + 24 VDC out (optionally 5 VDC)
2
+ 24 VDC out (optionally 5 VDC)
3 Channel A
3
Channel A
4 Channel B
4
Channel B
5 PE
5
PE
6 Channel A’
6
Channel A’
7 Channel B’
7
Channel B’
8 Channel Z (index pulse)
8
Channel Z (index pulse)
9 Channel Z’ (index pulse)
9
Channel Z’ (index pulse)
ST3
Inputs
ST4
Inputs
1-axis 8 I/O
1-axis 16 I/O 2-axis 16 I/O
1-axis 16 I/O
2-axis 16 I/O
1 0 V / GND
1
0 V / GND
0 V / GND
2 + 24 VDC out
2
+ 24 VDC out
+ 24 VDC out
3 Start
3
NC
NC
4 Stop
4
NC
NC
5 Reference
5
NC
Reference Y
6 Piece counter
6
NC
NC
7 Retract
7
NC
Retract Y
8 End min
8
NC
End min Y
9 End max
9
NC
End max Y
10 Displacement
10
NC
Displacement Y
ST5
Outputs
ST6
Outputs
1-axis 8 I/O 1-axis 16 I/O 2-axis 16 I/O
1-axis 16 I/O
2-axis 16 I/O
1 0 V / GND
1
0 V / GND
0 V / GND
2 + 24 VDC out
2
+ 24 VDC out
+ 24 VDC out
3 Drive signal 1 X
3
Auxiliary function 1
Drive signal 1 Y
4 Drive signal 2 X
4
Auxiliary function 2
Drive signal 2 Y
5 Drive signal 3 X
5
Auxiliary function 3
Drive signal 3 Y
6 Drive signal 4 X
6
Auxiliary function 4
Drive signal 4 Y
7 Position reached X
7
Reference runs
Position reached Y
8 Quantity reached X
8
NC
NC
9 Control enable X
9
NC
Control enable Y
10 Tolerance window X
10
NC
Tolerance zone Y
Содержание P40-000 Series
Страница 61: ...Accessories 61 Notes...